The AirTAC GFR200C08LJF1WT AirTAC Filter Regulator NPT1/4 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C08LJF1WT is an AirTAC GFR200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is built with 1/4 in NPT ports, a 5 um filter element (code W), a differential-pressure drain, low-pressure type regulation and an embedded square gauge scaled in MPa. Maximum inlet pressure is 1.0 MPa (145 psi), the operating temperature range is -5 to 70 C (non-freezing), and no mounting bracket is included with this code.
This is a genuine AirTAC part in the GFR series, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 in and options for drain type, filter grade, gauge scale, thread and bracket. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering.
| Model | GFR200C08LJF1WT AirTAC Filter Regulator NPT1/4 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeds filtered, regulated air to the solenoid valves and clamping cylinders on a machining centre, with the 5 um element helping keep fine debris out of valve seats.
Suits packaging and sealing lines that run their actuators at reduced pressure, where the low-pressure type regulator and built-in gauge let operators set and watch the line pressure.
Powers the air cylinders that gate, divert and stop product on conveyor lines, combining water and particle removal with pressure control at one take-off point.
Choose the size and port step against the air demand of your circuit: this unit is size 200 with 1/4 in NPT ports, and the GFR range steps up through 300, 400 and 600 for larger ports and flows. Drain on this code is differential-pressure; automatic and manual drains are available on other codes. The 5 um element suits circuits needing finer filtration than the 40 um standard. The square gauge is scaled in MPa, with psi and bar scales available on other codes. On thread: PT is the AirTAC standard, while G (BSPP) and NPT (this code) are order options; a mounting bracket can be added. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR flow as curves rather than a single rated figure, so we do not quote a number. Send us your application details and we will confirm the datasheet flow curve and sizing for the GFR200C08LJF1WT before you order.
The L in GFR200C08LJF1WT marks the low-pressure type regulator, intended for circuits set below the standard range. The exact adjustment range for this variant is not published in the material we hold, so we confirm it from the datasheet on request. Maximum inlet pressure remains 1.0 MPa (145 psi), and the gauge fitted is the embedded square type scaled in MPa.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.