verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR200 · Filter Regulator (filter + regulator in one body)

GFR200C08MJC2GK AirTAC Filter Regulator G1/4, 40 um

The AirTAC GFR200C08MJC2GK AirTAC Filter Regulator G1/4, 40 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$52.06 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR200C08MJC2GK AirTAC Filter Regulator G1/4, 40 um

The GFR200C08MJC2GK is an AirTAC GFR-series filter regulator: water and particulate filtration plus downstream pressure regulation combined in one body. This size-200 configuration has G1/4 ports (PT is the standard thread; G and NPT are order options), a 40 um filter element, a manual drain for bleeding collected condensate by hand, and a round gauge reading in psi. The standard regulator covers an adjustment range of 0.05-0.9 MPa (7-130 psi) with this manual-drain version, maximum inlet pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing). The bowl on this size is polycarbonate, and the J code means no mounting bracket is included.

This is a genuine AirTAC part from the GFR200 series, one of four sizes (200/300/400/600) with stepped ports and flow capacity. Across the range you can order a 5 um element (code W), automatic or differential-pressure drain instead of manual, a square embedded gauge or round external gauge with MPa, psi or bar scales, a reverse/check valve, and a mounting bracket. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application before ordering.

GFR200C08MJC2GK AirTAC Filter Regulator G1/4, 40 um Technical Specifications

ModelGFR200C08MJC2GK AirTAC Filter Regulator G1/4, 40 um
SeriesGFR200 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR200C08MJC2GK AirTAC Filter Regulator G1/4, 40 um

GFR200G-series filter regulator, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR200 · See datasheet · 40 µm
One size upGFR300
Add lubricationGFC200-C0 (two-unit set)

Where the GFR200C08MJC2GK AirTAC Filter Regulator G1/4, 40 um Is Used

conveyor_belt

Cartoner sealing station

Point-of-use air prep for the seal and tuck cylinders on a packaging cartoning line. The 40 um element catches pipe scale and compressor carryover before it reaches the valve stack, the manual drain lets an operator bleed accumulated condensate at shift start, and the psi gauge shows the set pressure at a glance.

precision_manufacturing

CNC pneumatic clamping

Filtered, regulated supply to the clamp/unclamp cylinders on a CNC machining cell. The regulator holds a steady downstream pressure for consistent clamping action, the round psi gauge reads the set point directly, and the fitted check valve guards the drop against backflow.

build

Pick-and-place robot cell

Compact filter-regulator mounted ahead of the gripper and cylinder valves on a robotic pick-and-place unit. One body handles both water/particulate removal and pressure regulation in the tight space of the robot dress pack, with the manual drain suited to cells serviced on a fixed schedule.

Is the GFR200C08MJC2GK AirTAC Filter Regulator G1/4, 40 um the Right Unit?

Start with the port step: size 200 with G1/4 is the entry point of the GFR range, and if your line's air demand sits near the top of what a 1/4 in drop can carry, step up to GFR300-10 or larger rather than oversizing the element. Choose the drain to match maintenance habits: manual (this model) needs an operator to bleed the bowl, automatic drains continuously, and differential-pressure drain (the default) purges on the pressure drop across the element. The 40 um element is standard for general plant air; specify the 5 um W option only where downstream valves or instruments need finer filtration. Gauge scale is your call - this unit carries a round psi gauge, and MPa or bar scales are available. Thread: PT is the standard; order G (BSPP) or NPT to match your piping. Brackets are optional on this model. Because flow is published as curves rather than a single rating, send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR200C08MJC2GK AirTAC Filter Regulator G1/4, 40 um FAQ

AirTAC publishes GFR flow as performance curves rather than a single rated number, so we do not quote a rated flow, Cv or SCFM figure for this unit. Tell us your application and required flow, and we will confirm the sizing against the datasheet curves on request before you order.

The M in the code means condensate collected in the bowl must be bled off by hand at the drain fitting, rather than discharged automatically. With a manual drain, the regulator adjustment range is 0.05-0.9 MPa (7-130 psi); automatic and differential-pressure drain versions start higher, at 0.15-0.9 MPa (20-130 psi). If nobody is on site to drain the bowl regularly, consider the automatic-drain version instead.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR200C08MJC2GK AirTAC Filter Regulator G1/4, 40 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR200C08MJC2GK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.