The AirTAC GFR200C08MJC2TK AirTAC Filter Regulator NPT1/4 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C08MJC2TK is a filter regulator: it removes water and particulate from compressed air and holds downstream pressure steady, in one body. This size 200 unit is threaded NPT 1/4, carries the standard 40 um filter element, drains by hand through its manual drain, and is fitted with an external round gauge scaled in psi plus a reverse (check) valve that holds downstream pressure if the upstream supply dips. No mounting bracket is included, and the bowl at this size is polycarbonate (PC).
This is a genuine AirTAC part from the GFR series, which spans sizes 200 to 600 with ports from 1/8 to 1 inch and PT, G or NPT threads. Maximum inlet pressure is 1.0 MPa (145 psi), the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi) on this manual-drain version, and the operating temperature range is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rating, so ask us to confirm the figures from the datasheet for your application.
| Model | GFR200C08MJC2TK AirTAC Filter Regulator NPT1/4 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding a small pneumatic press or clamping fixture: the 40 um element strips water and swarf from the shop-air line while the regulator holds a steady setting so the tool cycles consistently. The check valve keeps the press from losing pressure during upstream dips.
Supplying carton sealers, diverters and gate cylinders on a packaging conveyor, where a compact 1/4 in NPT drop is all that is needed. The manual drain suits a line that is bled at shift start, and the psi gauge lets operators verify the setting at a glance.
Regulating instrument air on a test rig or laboratory automation cell, where clean, stable low-pressure air matters and the round psi gauge gives a readable local indication. The compact size 200 body fits tight panels, though a bracket must be ordered separately.
Choose the size and port against the flow your line needs: size 200 with a 1/4 in NPT port suits compact supply points, while sizes 300, 400 and 600 carry larger ports and more flow. Drain type matters: manual drain needs an operator to bleed the bowl, automatic drains unattended, and differential-pressure drains on the pressure drop - note the regulation range differs (0.05-0.9 MPa / 7-130 psi for manual drain; 0.15-0.9 MPa / 20-130 psi for automatic or differential-pressure). Filter grade is 40 um standard; specify W for the 5 um element where finer filtration is needed. Gauges are embedded square as standard or external round, scaled in MPa, psi or bar - this unit has the round psi gauge. Thread here is NPT; PT and G are order options, and a bracket can be added if you need panel fixing. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves in the datasheet, not as a single rated number, so we do not quote a figure here. Tell us your application and required conditions and we will confirm the flow and sizing from the datasheet on request.
M means manual drain: an operator opens the drain to expel water collected in the polycarbonate bowl, which suits accessible points bled on a schedule. If the unit is hard to reach, choose the automatic-drain version instead. Note the regulation range also differs: 0.05-0.9 MPa (7-130 psi) for manual drain versus 0.15-0.9 MPa (20-130 psi) for automatic or differential-pressure drain.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.