The AirTAC GFR200C08MJC2WT AirTAC Filter Regulator NPT1/4 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C08MJC2WT is a filter regulator: one body that removes water and particulate from compressed air and holds downstream pressure at your setpoint. This 200-size unit is tapped 1/4 in NPT, carries the 5 um element (code W) for finer filtration than the standard 40 um, drains by hand through its manual drain, and reads the setpoint on a round psi gauge. It is the standard (not low-pressure) regulator version, supplied without a mounting bracket, and fitted without a reverse/check valve.
This is a genuine AirTAC part. The GFR family spans sizes 200 to 600 with ports from 1/8 to 1 in, a choice of PT, G (BSPP) or NPT thread, manual, automatic or differential-pressure drains, 40 um or 5 um elements, and a range of gauge options. Maximum inlet pressure is 1.0 MPa (145 psi) and working temperature is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm the sizing figures from the datasheet for your application.
| Model | GFR200C08MJC2WT AirTAC Filter Regulator NPT1/4 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeds the pneumatic capping heads on a beverage bottling line: the 5 um element keeps particles out of the capper valves while the regulator holds a steady set pressure for consistent cap tightening.
Supplies regulated air to stopper and pusher cylinders on a carton packaging conveyor; the manual drain suits a shift pattern where an operator bleeds the bowl at start-up, and the psi gauge gives a readable setpoint.
Prepares air for pneumatic clamps on a CNC machining fixture: filtered, regulated air at a set psi supports repeatable clamping, and the 5 um grade helps protect the clamp cylinder's control valve.
Choose the size by port and demand: this 200 unit takes 1/4 in, while 300, 400 and 600 step up both port and flow capacity - match the published curve to your requirement rather than any single rated figure. Pick the drain: manual (this unit) where an operator drains the bowl on a routine, automatic for unattended condensate removal, or the differential-pressure default. Pick the element: 40 um standard or 5 um (code W) for finer protection of downstream equipment. Gauge choices are the embedded square gauge or an external round gauge, scaled in MPa, psi or bar - this unit carries a round psi gauge. Thread is NPT here; PT is the standard and G (BSPP) is also a catalogue option. The bracket is omitted (code J) but can be specified. Because flow is published as curves, not a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR flow as curves, not a single rated number, so we do not quote a rated flow, Cv or SCFM. Tell us your inlet pressure and air demand and we will confirm the sizing figures from the datasheet on request.
This unit's manual drain (code M) empties the bowl when an operator opens it, which suits attended cells drained on a routine. If the unit sits where nobody drains it regularly, choose the automatic drain (code A) or the differential-pressure default instead - both are catalogue options in the same size.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.