The AirTAC GFR200C08MLC1T AirTAC Filter Regulator 1/4 NPT Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C08MLC1T is a filter regulator: it removes water and particulate from compressed air and holds a reduced downstream pressure in one body. This size 200 unit is threaded 1/4 in NPT, carries the standard 40 um filter element and has a manual-drain bowl in polycarbonate (PC). It is the low-pressure regulator type, is supplied with a mounting bracket and a round pressure gauge scaled in MPa, and handles a maximum inlet pressure of 1.0 MPa (145 psi) between -5 and 70 C (non-freezing).
This is a genuine AirTAC part. The GFR family spans sizes 200 to 600 with ports from 1/8 to 1 in, a choice of manual, automatic or differential-pressure drains, 40 um or 5 um (W) elements, gauge styles and scales, and G or NPT thread options. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.
| Model | GFR200C08MLC1T AirTAC Filter Regulator 1/4 NPT Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Conditioning the supply to a low-pressure clamping cylinder on a machining fixture, where filtered air and a steady reduced pressure protect the workpiece from over-clamping.
Point-of-use conditioning for the low-pressure actuators on a carton-sealing line, keeping moisture and debris out of the valve stack downstream of the unit.
Filtering and regulating the air feeding pick-and-place grippers on an assembly cell, where the low-pressure regulator type suits gentle part handling.
Size and port set the air capacity: the GFR200 with its 1/4 in NPT port suits compact circuits, while GFR300, 400 and 600 step up for larger ports and higher demand - match the size to your air consumption rather than to the pipe alone. Drain choice matters: manual drains need periodic bleeding, while automatic and differential-pressure drains discharge condensate on their own. This unit carries the standard 40 um element; specify code W for the 5 um grade if downstream equipment needs finer filtration.
Other decodable choices are the gauge (embedded square as standard, external round optional, in MPa, psi or bar scales - this model has the round MPa gauge), the thread (PT is the standard; G and NPT are order options) and the bracket. The low-pressure regulator type has a limited adjustment range that is not published as a single figure, and flow is given as curves, not a rating - ask us to confirm both against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR flow as performance curves rather than a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the datasheet curve and the correct size before you order.
The M in the code sets a manual drain: condensate collects in the PC bowl until you open the drain by hand, which suits installations checked on a routine schedule. The L sets the low-pressure regulator type, whose adjustment range is limited compared with the standard type; ask us to confirm the exact range for your setpoint.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.