The AirTAC GFR200C08MLC1WT AirTAC Filter Regulator 1/4 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C08MLC1WT is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is built on the GFR200 size with 1/4 in NPT ports, a 5 um filter element (the W grade; 40 um is the standard option), a manual drain, and the low-pressure regulator type, whose exact adjustment range is not published - confirm your set pressure with us. A round pressure gauge with an MPa scale is fitted, a mounting bracket is included, and the bowl is metal. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. GFR200 is the compact size in the GFR family, which steps up through 300, 400 and 600 with port sizes from 1/8 in to 1 in and a choice of PT, G or NPT thread, differential-pressure, automatic or manual drain, 40 um or 5 um filtration, and gauge scale in MPa, psi or bar. Because AirTAC publishes flow only as curves rather than a single rating, we confirm flow and datasheet figures for your application on request.
| Model | GFR200C08MLC1WT AirTAC Filter Regulator 1/4 in NPT |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Filtered, regulated air for the low-pressure control circuits that actuate filling valves and capping cylinders on a bottling line; the 5 um element protects pilot valves from water and particulate.
Point-of-use filter regulator ahead of spray guns in a paint booth: 5 um filtration cleans the air while the low-pressure regulator holds a gentle, repeatable gun pressure, and the manual drain is emptied during each shift check.
Bracket-mounted inside a machine's pneumatic control panel, it conditions the 1/4 in NPT branch feed to solenoid valves and small cylinders, with the MPa gauge giving operators a local pressure readout.
Choose the size by the port and flow step: GFR200 carries 1/4 in ports here, and the 300, 400 and 600 bodies step up in port and flow capacity. Pick the drain to match maintenance: this unit has a manual drain (code M), so someone must drain the bowl by hand; automatic and differential-pressure drains are available in the family for unattended installations. The 5 um element (code W) gives finer protection than the standard 40 um grade. The fitted round gauge reads in MPa, with psi and bar scales available as options. NPT is specified here, PT is the standard thread and G is available to order, and the mounting bracket is included. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes G-series flow as curves rather than a single rated figure, so we do not quote a number here. Send us your application details - required pressure and the equipment it supplies - and we will confirm the flow from the datasheet before you order.
The M in the code is the drain type: condensate collects in the metal bowl and must be drained by hand at the drain fitting. If the installation runs unattended, ask about GFR configurations with an automatic or differential-pressure drain instead.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.