The AirTAC GFR200C08MLC2T AirTAC Filter Regulator NPT1/4 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C08MLC2T is a size 200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration carries a 1/4 in NPT port, a 40 um filter element, a manual drain bowl in polycarbonate, and the low-pressure regulator type. A round pressure gauge with a psi scale is fitted, and a mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR family is available in sizes 200, 300, 400 and 600 with a choice of port sizes, PT, G or NPT threads, manual, automatic or differential-pressure drains, a 40 um standard or 5 um (W) filter grade, standard or low-pressure regulation, gauge style and scale, and a reverse/check valve option. Flow figures are published as curves rather than a single rating, so ask us to confirm sizing and datasheet details for your application.
| Model | GFR200C08MLC2T AirTAC Filter Regulator NPT1/4 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
On an assembly bench where clamps hold workpieces at a reduced, stable pressure, this filter regulator cleans the shop air and lets an operator set the clamping force from the fitted psi gauge.
At a spray-gun station running below normal line pressure, the low-pressure regulator type suits the reduced set point while the 40 um element and drain bowl keep water and debris out of the gun.
Feeding the small cylinders on a carton-sealing or labelling conveyor, the unit filters the supply, holds a gentle regulated pressure for delicate product handling, and drains collected condensate by hand at shift checks.
Start with the size and port: 200 is the smallest GFR frame, and the 08 position gives a 1/4 in port here, but the right step depends on the flow your line needs - we can check the published flow curves against your demand before you order. Choose the drain to match maintenance: this unit has a manual drain, which needs periodic draining by hand; automatic and differential-pressure drains are available on other codes. The 40 um element is the standard grade; specify W for the 5 um grade where finer filtration is needed. This code is the low-pressure regulator type - its exact adjustment range is not published, so confirm it with us if your set pressure is critical. The fitted round gauge reads in psi; square gauges and MPa or bar scales are options. Thread is NPT here, with PT (standard) and G available to order, and a mounting bracket is included.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for this family as curves rather than a single rated figure, so we do not quote a number. Send us your application details and we will confirm the flow curve and datasheet figures for this exact model on request before you order.
The M in this code means the drain bowl is emptied by hand, so it should be drained periodically as part of routine checks. If you prefer unattended condensate removal, GFR codes with an automatic (A) or differential-pressure (blank) drain are available - ask us for the right variant.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.