The AirTAC GFR200C08MLC2WG AirTAC Filter Regulator G1/4, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C08MLC2WG is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This size 200 unit is built around a G1/4 (BSPP) port, carries the finer 5 um filter element (code W; 40 um is the standard grade), a manual drain on the bowl, and a low-pressure regulator fitted with a round gauge reading in psi. The polycarbonate bowl suits the -5 to 70 C (non-freezing) operating range, maximum inlet pressure is 1.0 MPa (145 psi), and a mounting bracket is included.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, and can be ordered with manual, automatic or differential-pressure drains, a 40 um or 5 um element, an embedded square gauge or an external round gauge in MPa, psi or bar scales, and PT, G or NPT threads. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application.
| Model | GFR200C08MLC2WG AirTAC Filter Regulator G1/4, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding small gripper and cylinder circuits on a robotic pick-and-place cell, where the low-pressure regulator holds a modest setpoint and the 5 um element protects seals and valve seats from water and fine dirt.
Conditioning the compressed-air feed to lab rigs and test benches that need clean, low-pressure air at a 1/4 in connection, with the round gauge giving a direct psi readout that matches the bench instrumentation.
Trimming supply pressure inside a machine's pneumatic control panel, where the combined filter-regulator body saves space over separate units and the included bracket simplifies sub-panel mounting.
Choose the size by the port and flow step: size 200 with a 1/4 in connection is the compact end of the GFR range, and stepping up to 300, 400 or 600 raises both the port and the capacity. This unit is already specified with the finer 5 um element (W) instead of the 40 um standard, a manual drain (M) instead of automatic or differential-pressure, a round psi gauge (C2), a G (BSPP) thread instead of the PT standard or the NPT option, and the low-pressure regulator type (L). Because flow is published as curves rather than a single rating, send us your flow and pressure requirements and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number here. Send us your flow and upstream/downstream pressure conditions and we will confirm the figures from the datasheet for this exact configuration.
Code M specifies a manual drain: accumulated water must be drained from the bowl by hand at intervals you set based on humidity and usage. If you would rather not do this, the same size is available with an automatic or differential-pressure drain - ask us for the alternative code.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.