The AirTAC GFR200C08MLF2G AirTAC Filter Regulator G1/4 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C08MLF2G is a filter regulator: it removes water and particulate from compressed air and holds the downstream pressure at your set point in one compact body. This GFR200 configuration comes with a G1/4 (BSPP) port, a manual drain for scheduled bowl draining, a 40 um standard filter element, the low-pressure regulator type, an embedded square gauge scaled in psi, a metal bowl and a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, and options that include automatic or differential-pressure drains, a 5 um element (code W), alternative gauge scales, G or NPT threads and check-valve versions. We confirm flow figures and the full datasheet on request, since AirTAC publishes flow as curves rather than a single rating.
| Model | GFR200C08MLF2G AirTAC Filter Regulator G1/4 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Filtered, regulated air feeds the directional valves on a carton-forming machine; the manual drain is emptied during scheduled changeover checks.
On a machining cell's clamp fixture, the unit strips water and particulate from shop air and holds the clamp circuit at its set pressure.
At bench assembly stations, the filter regulator conditions the drop line feeding air tools and cylinders, with the psi gauge giving operators a local pressure readout.
Size and port step up from 200 to 600 as flow demand grows; this unit is the 200 size with a 1/4 in port. Drain choice matters: manual (as here) needs periodic bowl draining, while automatic and differential-pressure drains empty the bowl without operator attention. Filter grade is 40 um standard or 5 um with code W for finer particulate. Gauge scales are MPa, psi or bar, and threads come as PT (standard), G or NPT to order; brackets are optional across the family and included here. Because AirTAC publishes flow as curves rather than a single rated figure, ask us to confirm sizing against your application - and the low-pressure type's adjustment range - before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote one number. Tell us your application and we will confirm the flow data from the datasheet on request.
This unit uses a manual drain: open it periodically to empty collected water. The GFR family also offers automatic and differential-pressure drains; choose those where the installation is hard to reach. Ask us to quote the alternative drain codes.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.