The AirTAC GFR200C08MLJC2K AirTAC Filter Regulator 1/4 in PT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C08MLJC2K is an AirTAC GFR-series filter regulator: water and particulate filtration plus pressure regulation combined in a single body, with a drain bowl but no lubricator. This size 200 configuration carries a 1/4 in PT port, a polycarbonate bowl with manual drain, the standard 40 um filter element, and the low-pressure regulator type. It is fitted with an external round gauge reading in psi and a reverse/check valve, and is supplied without a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, and options include differential-pressure, automatic or manual drains, a 5 um element (code W), an embedded square gauge or an external round gauge in MPa, psi or bar scales, G (BSPP) or NPT threads, and a mounting bracket. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.
| Model | GFR200C08MLJC2K AirTAC Filter Regulator 1/4 in PT |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
On a carton-sealing or hot-glue head line, the filter section strips water and pipe scale that would stain product or gum valves, while the low-pressure regulator holds a gentle, steady supply to the sealing actuators. The manual drain suits a line that is attended every shift, and the psi gauge lets operators read and set the setting in familiar units.
Light-duty clamps and swing cylinders on a CNC cell often need a lower, carefully held supply pressure than the main header delivers. This unit filters the shop air feeding the fixture circuit and regulates it down in one body, with the reverse/check valve helping hold the setting if upstream supply dips mid-cycle.
Conveyor diverter gates, pusher fingers and stopper cylinders run best on a clean, moderate supply so product is nudged rather than slammed. Mounted at the take-off for the conveyor's air drop, this unit removes condensate and grit ahead of the valves and lets the line setter dial in the working pressure on the round psi gauge.
Step through the real choices before ordering. Size and port scale together: this unit is size 200 with a 1/4 in PT port, and the family runs up to size 600 with a 1 in port, so pick the step that matches your line's flow demand. Drain type matters in service: this unit is manual drain, which an operator empties periodically; automatic and differential-pressure drains are available where the bowl should clear itself. Filter grade is 40 um standard, with the W code giving a 5 um element where finer particulate matters. On the gauge side, an embedded square gauge is standard and an external round gauge is optional, in MPa, psi or bar scales - this configuration carries a round psi gauge. Thread is PT as standard, with G (BSPP) and NPT as order options, and the J code omits the mounting bracket as it does here. Flow is published as curves, not a single rating, so send us your flow and pressure requirements and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote one number. Tell us your required flow and upstream pressure and we will confirm the sizing against the datasheet on request before you order.
The bowl collects water and particulate separated from the compressed air, and a manual drain means an operator opens it to empty the bowl at intervals. Choose manual where the unit is visited regularly as part of routine checks; if the installation runs unattended, the same family is available with automatic or differential-pressure drains instead.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.