The AirTAC GFR200C08MLJC2TK AirTAC Filter Regulator 1/4 NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C08MLJC2TK is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This 200-size unit carries a 1/4 in NPT port, the low-pressure regulator type, a manual drain on the metal bowl, the standard 40 um filter element, a round pressure gauge reading in psi, and a reverse/check valve. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. No mounting bracket is included with this configuration.
This is a genuine AirTAC part. The GFR family spans sizes 200 to 600 with ports from 1/8 to 1 in, and options across the range include automatic, manual or differential-pressure drains, a finer 5 um element (code W), gauge scales in MPa, psi or bar, and G or NPT threads in place of the PT standard. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet and sizing figures for your application before ordering.
| Model | GFR200C08MLJC2TK AirTAC Filter Regulator 1/4 NPT |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Filtered and regulated air feeds glue applicators and hold-down cylinders on packaging machines that run at modest set pressures, where the low-pressure regulator variant is the right match and the manual drain is emptied during scheduled changeovers.
Clean, pressure-controlled air actuates low-pressure clamp circuits on fixture plates, with the 40 um element protecting valve spools and the round psi gauge giving the operator a direct set-point readout at the fixture.
Regulated low-pressure air strips rinse droplets and dust from bottles before labelling, with the filter stage keeping water and particulate out of the nozzles and the reverse/check valve holding the circuit against backflow.
Start with size and port: GFR units step from 200 to 600 with ports from 1/8 to 1 in, matched against the air demand of your line - because flow is published as curves, not a single rating, ask us to check the curve for this model against your requirement before ordering. This unit is the low-pressure type (code L); the exact regulation range for the low-pressure variant is not published in the material we hold, so confirm it with us if your set pressure is critical. Drain style is a real choice: this configuration is manual (M), while automatic (A) and differential-pressure (blank) versions drain the bowl without operator attention. The 40 um element is standard here; specify code W for the 5 um grade where finer filtration is needed. A gauge is fitted in this build (round, psi scale); the embedded square gauge is the standard style and MPa, psi or bar scales are available. Thread is NPT on this unit; PT is the catalogue standard and G (BSPP) is an order option. This configuration omits the mounting bracket (code J); bracketed versions are available.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR flow as curves, not as a single rated figure, so we do not quote a number here. Send us your inlet pressure, set pressure and air demand, and we will confirm the flow from the datasheet for this exact model before you order.
The metal bowl collects water and particulate removed from the air, and with a manual drain an operator opens the drain by hand to expel it - it does not discharge on its own. If you want unattended draining, the same unit is available with an automatic (A) or differential-pressure (blank) drain; ask us for that variant.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.