The AirTAC GFR200C08MLJC2WG AirTAC Filter Regulator G1/4 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C08MLJC2WG is an AirTAC GFR200 filter regulator: it removes water and particulate from compressed air and holds a set downstream pressure in one body. This configuration carries a G1/4 port, a metal bowl with manual drain, a 5 um filter element (the finer of the two published grades), the low-pressure regulator type, an external round gauge reading in psi, and no mounting bracket. Because it is the low-pressure type, its adjustment range is not the standard published figure; ask us to confirm the exact range for your setpoint.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, PT as the standard thread and G or NPT orderable, with manual, automatic or differential-pressure drains, 40 um or 5 um elements, embedded square or external round gauges in MPa, psi or bar scales, and bracket options. Rated flow is published as curves rather than a single figure, so we confirm datasheet and sizing figures on request.
| Model | GFR200C08MLJC2WG AirTAC Filter Regulator G1/4 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding the clamping cylinders of a small pneumatic press where the circuit calls for low-pressure regulation; the regulator holds the setpoint while the 5 um element keeps scale and pipe debris out of the valve seats.
Conditioning the air feeding coating and test instruments in a lab, where the psi gauge lets technicians read setpoints directly and the manual drain supports a scheduled blowdown during shift checks.
Mounted at the inlet of a packaging machine's valve-island sub-panel, removing water and 5 um particulate ahead of the solenoid valves while regulating supply to the actuator circuits.
Choose the size by port and required flow: this unit is size 200 with a G1/4 port; step up to 300, 400 or 600 when the line needs a larger port and more flow. The M in this code selects a manual drain, so an operator opens the bowl drain to release collected water; automatic (A) and differential-pressure (blank) drain codes are available if you want unattended removal. The 5 um element (code W) suits points where finer particulate matters, while 40 um is the standard grade. The round gauge here reads in psi; embedded square gauges and MPa or bar scales are alternatives. Thread is G on this unit, with PT as the standard and NPT orderable; a bracket is optional and this configuration is supplied without one. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes G-series flow as performance curves rather than a single rated figure, so there is no one l/min or SCFM number we can quote for the GFR200C08MLJC2WG. Send us your line pressure and air demand and we will confirm the datasheet curve and sizing on request.
The M in the code selects a manual drain: an operator opens the bowl drain to release collected water, which suits stations that are checked on a schedule. If the unit will sit unattended, the same GFR200 size is available with automatic (A) or differential-pressure (blank) drain codes; tell us and we will identify the matching model.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.