The AirTAC GFR200C08MLJF2T AirTAC Filter Regulator NPT1/4 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C08MLJF2T is an AirTAC GFR-series filter regulator: water and particulate filtration plus pressure regulation combined in a single body. This size 200 unit has a 1/4 in NPT port, a manual drain bowl, the standard 40 um filter element, and a low-pressure regulator type for circuits that run below standard line pressures. An embedded square gauge with a psi scale is fitted, and no mounting bracket is included.
This is a genuine AirTAC part. The GFR family spans sizes 200 to 600 with port sizes from 1/8 to 1 in, drain choices (manual, automatic or differential-pressure), an optional 5 um element (code W), PT as the standard thread with G and NPT as order options, and gauge scales in MPa, psi or bar. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm figures against your application.
| Model | GFR200C08MLJF2T AirTAC Filter Regulator NPT1/4 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Point-of-use conditioning for a carton-sealing or wrapping machine: filtered, regulated air to the cylinders and directional valves that drive the sealing head, with the low-pressure type suiting circuits set below standard line pressure.
Feed a bench pneumatic press or clamping fixture where the operator sets a stable working pressure on the psi gauge and drains accumulated water from the bowl manually at the start of each shift.
Condition air for filler or capper actuation on a beverage line, keeping water and particulates out of the control valves while holding the lower pressure the circuit requires.
Size and port step up from 200 to 600 as flow demand grows; this unit is size 200 with a 1/4 in NPT port. Drain type is a real choice: manual means the bowl is emptied by hand at intervals, while automatic and differential-pressure versions drain themselves - this code carries the manual drain. The standard element is 40 um; specify W for the 5 um grade where finer filtration is needed. The fitted gauge reads in psi; MPa and bar scales are available. PT is the standard thread and G (BSPP) or NPT are ordered as options, and a mounting bracket is optional. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow and the full datasheet figures for this unit on request.
This code carries the M drain option: condensate collects in the bowl and must be drained by hand at intervals. If you would rather not do that, the same size is available with automatic or differential-pressure drain. The regulation range for this low-pressure type is confirmed with the datasheet on request.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.