verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR400C10AJC2WT AirTAC Filter Regulator NPT3/8 5 um

The AirTAC GFR400C10AJC2WT AirTAC Filter Regulator NPT3/8 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$79.64 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR400C10AJC2WT AirTAC Filter Regulator NPT3/8 5 um

The GFR400C10AJC2WT is an AirTAC GFR400 filter regulator: a single body that removes water and particulate from compressed air and then regulates downstream pressure, in that order. This configuration is sized for a 3/8 in NPT port, carries the fine 5 um filter element (the W grade, one step finer than the standard 40 um), drains condensate automatically, and is fitted with an external round gauge reading in psi. The standard regulator covers an adjustment range of 0.15-0.9 MPa (20-130 psi), maximum inlet pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing). The polycarbonate bowl suits the 400 size, and no mounting bracket is included in this variant.

This is a genuine AirTAC part. The GFR family is published in four sizes (200, 300, 400, 600) with port options from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drain, 40 um or 5 um filtration, gauge style and scale options, and PT, G or NPT threads. Flow is published as curves rather than a single rated figure, so we confirm the datasheet and flow figures for your application on request.

GFR400C10AJC2WT AirTAC Filter Regulator NPT3/8 5 um Technical Specifications

ModelGFR400C10AJC2WT AirTAC Filter Regulator NPT3/8 5 um
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR400C10AJC2WT AirTAC Filter Regulator NPT3/8 5 um

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the GFR400C10AJC2WT AirTAC Filter Regulator NPT3/8 5 um Is Used

precision_manufacturing

Pneumatic press and clamping fixtures

Feeding cleaned, regulated air to the cylinders of a clamping or light-press station, where the 5 um element protects directional valves and the psi gauge lets setters dial in the clamp pressure.

conveyor_belt

Packaging and case-sealing lines

Air preparation for conveyor-mounted carton sealers and labeling heads that run unattended shifts, using the automatic drain to clear condensate without a daily bowl check.

science

Laboratory and test-bench air supply

Supplying regulated air to bench-top test rigs and analytical equipment that need finer-than-standard filtration and a stable, locally adjustable pressure setpoint.

Is the GFR400C10AJC2WT AirTAC Filter Regulator NPT3/8 5 um the Right Unit?

Size and port are the first decision: the 400 body with its 3/8 in NPT port suits lines drawing more air than a 300 unit, but the right step depends on the flow your circuit actually needs - ask us to check the published flow curve against your consumption before ordering. The 5 um element (code W) is the right choice where downstream valves, cylinders or instruments are sensitive to finer particles; the standard 40 um element remains available if coarse protection is enough. The automatic drain expels collected condensate without operator attention, which suits unmanned or hard-to-reach installations; manual and differential-pressure drain versions exist for other setups. The round psi gauge is fitted here; square embedded gauges and MPa or bar scales are alternatives. NPT is the thread on this unit, with PT and G available as order options, and a bracket can be added if this J-coded, bracket-less variant needs panel fixing.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR400C10AJC2WT AirTAC Filter Regulator NPT3/8 5 um FAQ

AirTAC publishes flow for the GFR400 series as curves rather than a single rated number, so we do not quote a figure that could mislead your sizing. Tell us your working pressure and air consumption and we will confirm the flow from the datasheet for this exact model on request.

The A in the code means condensate collected in the bowl is discharged automatically as it accumulates, so the unit does not depend on an operator opening the drain. That suits enclosed cabinets, rooftop or remote installations, and multi-shift lines. Manual-drain and differential-pressure-drain versions of the same GFR400 body are available if your maintenance routine prefers them.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR400C10AJC2WT AirTAC Filter Regulator NPT3/8 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C10AJC2WT and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.