verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR400C10ALC2W AirTAC Filter Regulator 3/8" PT, 5 um

The AirTAC GFR400C10ALC2W AirTAC Filter Regulator 3/8" PT, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$80.46 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR400C10ALC2W AirTAC Filter Regulator 3/8" PT, 5 um

The GFR400C10ALC2W is an AirTAC GFR400 filter regulator: one body that removes water and particulate from compressed air and then regulates downstream pressure. This configuration is the 400 size with PT3/8 ports (PT thread standard; G and NPT are order options), a 5 um filter element (code W, against the 40 um standard), an automatic drain that expels collected condensate without manual attention, and the low-pressure regulator type for applications set below standard working ranges. It carries a round external gauge scaled in psi, includes a mounting bracket, and has no reverse/check valve fitted. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600, with a choice of port, drain type (differential-pressure, automatic or manual), filter grade (40 um standard, 5 um optional), gauge style and scale, and thread form. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.

GFR400C10ALC2W AirTAC Filter Regulator 3/8" PT, 5 um Technical Specifications

ModelGFR400C10ALC2W AirTAC Filter Regulator 3/8" PT, 5 um
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR400C10ALC2W AirTAC Filter Regulator 3/8" PT, 5 um

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the GFR400C10ALC2W AirTAC Filter Regulator 3/8" PT, 5 um Is Used

factory

Packaging line cylinder supply

Point-of-use air preparation for a packaging machine's cylinder and actuator circuits: the 5 um element protects directional valves from water and fine particulate, the automatic drain keeps condensate off the shop floor without operator rounds, and the low-pressure regulator holds a gentle working pressure for delicate sealing and forming motions.

science

Laboratory and instrumentation air

Conditioning the air feed to lab benches, analytical instruments and pneumatic sample-handling rigs, where the 5 um grade and stable low-pressure regulation protect sensitive components, the psi-scaled round gauge gives operators a familiar readout, and the automatic drain suits equipment that runs unattended.

precision_manufacturing

Low-pressure clamping and fixture circuits

Supplying regulated air to clamping fixtures and light assembly tooling that must not be over-pressed: the low-pressure regulator type is chosen for circuits set below standard working pressures, the 5 um element keeps spool valves and check valves clean, and the included bracket allows tidy panel-side mounting at the cell.

Is the GFR400C10ALC2W AirTAC Filter Regulator 3/8" PT, 5 um the Right Unit?

Start with the port step: the 400 size here is PT3/8, and the family steps through 1/8" to 1" across sizes 200-600, so match the size to the air demand of the circuit rather than upsizing blindly - and let us confirm the flow curve against your consumption. Drain type is a real choice: differential-pressure (the default) drains only when the pressure drop warrants it, automatic drains continuously without attention, and manual requires operator action; this unit is automatic, which suits unmanned or intermittently attended installations. The 5 um element (code W) is the finer option against the 40 um standard - choose it where downstream valves and instruments are sensitive to finer particulate. Gauge options are the embedded square gauge or an external round gauge, in MPa, psi or bar scales; this unit has a round psi gauge. Thread is PT as standard with G (BSPP) and NPT as order options, and a mounting bracket is included. Note this is the low-pressure regulator type (code L); its exact adjustment range is not published in the material we hold, so confirm it with us. Because flow is published as curves and not a single rating, ask us to verify sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR400C10ALC2W AirTAC Filter Regulator 3/8" PT, 5 um FAQ

AirTAC publishes flow for the GFR family as performance curves rather than a single rated figure, so there is no one rated flow number we can honestly quote. Tell us your operating pressure and air consumption and we will confirm the flow curve and correct sizing from the datasheet on request before you order.

The A in the code GFR400C10ALC2W selects the automatic drain, which expels collected condensate from the bowl without operator attention. The family also offers a differential-pressure drain (the default, which drains when the pressure drop warrants it) and a manual drain (code M, drained by hand). Automatic suits unmanned or intermittently attended installations; manual suits supervised points where you want full control over discharge.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR400C10ALC2W AirTAC Filter Regulator 3/8" PT, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C10ALC2W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.