verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR400C10ALC2WT AirTAC Filter Regulator 3/8 in NPT

The AirTAC GFR400C10ALC2WT AirTAC Filter Regulator 3/8 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$80.81 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR400C10ALC2WT AirTAC Filter Regulator 3/8 in NPT

The AirTAC GFR400C10ALC2WT is a filter regulator: filtration and pressure regulation combined in one body, so a single unit removes water and particulate from the compressed air and holds the downstream pressure where the circuit needs it. This size 400 configuration is tapped 3/8 in NPT, carries a 5 um filter element (the finer of the two published grades), drains condensate automatically, and is fitted with a round pressure gauge scaled in psi. The regulator is the low-pressure type, and the unit includes a mounting bracket and a metal bowl. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GFR family is published in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drain, 40 um or 5 um filtration, standard or low-pressure regulation, and PT, G or NPT threads. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application on request.

GFR400C10ALC2WT AirTAC Filter Regulator 3/8 in NPT Technical Specifications

ModelGFR400C10ALC2WT AirTAC Filter Regulator 3/8 in NPT
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR400C10ALC2WT AirTAC Filter Regulator 3/8 in NPT

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the GFR400C10ALC2WT AirTAC Filter Regulator 3/8 in NPT Is Used

factory

Assembly cell air drops

Point-of-use air preparation for pneumatic cylinders and air tools at an automotive assembly cell: the 5 um element strips water and fine particulate before they reach the tools, while the regulator holds a steady supply pressure at the drop.

conveyor_belt

Bottling line conveyor valves

Conditioning the air feeding directional valves and conveyor stopper cylinders on a bottling line, where condensate in the supply causes sticky spools; the automatic drain keeps the bowl clear without a stop for manual draining.

valve

Paint finishing line supply

Filtered, regulated air ahead of the spray-gun circuit on a low-pressure finishing line, where the low-pressure regulator type and fine 5 um element suit coating work that is sensitive to dirt and pressure drift.

Is the GFR400C10ALC2WT AirTAC Filter Regulator 3/8 in NPT the Right Unit?

Start with size and port: the 200 to 600 steps rise in port size and flow capacity, and this unit sits at size 400 with a 3/8 in NPT port - match the step to the air demand of the circuit rather than to the pipe alone. Then set the drain: automatic (as here) empties the bowl without operator attention, manual needs periodic draining, and the differential-pressure default drains on a pressure drop. Filter grade is 40 um standard or 5 um (code W) as fitted here; the gauge can be the embedded square type or an external round gauge, scaled in MPa, psi or bar. Thread is PT as standard with G and NPT as order options, and the bracket can be included or omitted. Because flow is published as curves rather than a single rated figure, send us your application and we will confirm sizing from the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR400C10ALC2WT AirTAC Filter Regulator 3/8 in NPT FAQ

AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow and sizing from the datasheet on request.

This configuration drains condensate from the bowl automatically, so it keeps working without operator attention - useful on lines that run unattended. Manual drain needs periodic draining and the differential-pressure default drains on a pressure drop; all three are published options across the GFR family.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR400C10ALC2WT AirTAC Filter Regulator 3/8 in NPT

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C10ALC2WT and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.