verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR400C10ALF2T AirTAC Filter Regulator NPT3/8

The AirTAC GFR400C10ALF2T AirTAC Filter Regulator NPT3/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$80.77 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR400C10ALF2T AirTAC Filter Regulator NPT3/8

The GFR400C10ALF2T is an AirTAC GFR-series filter regulator: it removes water and particulate from compressed air and holds downstream pressure in a single body. This size 400 unit is built with a 3/8 in NPT port, an automatic drain that expels collected condensate without manual attention, a 40 um standard filter element, and the low-pressure regulator type with an embedded square gauge reading in psi. A mounting bracket is included, and the polycarbonate bowl is the standard material for this size.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, drain choices (differential-pressure, automatic or manual), an optional 5 um element (code W), gauge scales in MPa, psi or bar, and PT, G or NPT threads. Operating limits are 1.0 MPa (145 psi) maximum inlet pressure and -5 to 70 C (non-freezing). Flow is published as curves rather than a single rating, so ask us to confirm sizing and the full datasheet for your application.

GFR400C10ALF2T AirTAC Filter Regulator NPT3/8 Technical Specifications

ModelGFR400C10ALF2T AirTAC Filter Regulator NPT3/8
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR400C10ALF2T AirTAC Filter Regulator NPT3/8

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the GFR400C10ALF2T AirTAC Filter Regulator NPT3/8 Is Used

precision_manufacturing

Assembly-cell clamping circuit

Feeding pneumatic clamps and swing cylinders on an assembly fixture, where filtered air and a steady low-pressure setting keep the clamping action repeatable through a full shift.

conveyor_belt

Packaging conveyor gating

Supplying the gating and diverting cylinders on a packaging conveyor line, with the automatic drain handling condensate at a drop point nobody visits during a run.

factory

Plant air drop for low-pressure actuators

Serving as a filtered, regulated drop point on a plant air main feeding low-pressure actuators and air cylinders, with the square psi gauge giving operators a local pressure readout.

Is the GFR400C10ALF2T AirTAC Filter Regulator NPT3/8 the Right Unit?

When choosing within the GFR range, step up through sizes 200, 300, 400 and 600 as your port size and air demand grow; this unit sits at size 400 with a 3/8 in NPT port. Drain type is a real decision: the automatic drain fitted here suits drop points that are not easily reached, manual drain suits attended stations, and the differential-pressure default drains only when the pressure differential calls for it. Filter grade is 40 um standard, with 5 um (code W) where finer particulate protection matters. Gauge scale (MPa, psi or bar), thread (PT standard, G or NPT to order) and the included bracket complete the configuration. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR400C10ALF2T AirTAC Filter Regulator NPT3/8 FAQ

AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote one number here. Tell us your port size, working pressure and air demand, and we will confirm the flow from the datasheet for this exact unit.

This unit carries code A, the automatic drain, which expels collected condensate on its own - useful at unattended drop points. The GFR family is also available with manual drain or the differential-pressure default; tell us which suits the installation and we will quote that variant.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR400C10ALF2T AirTAC Filter Regulator NPT3/8

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C10ALF2T and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.