verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR400C10ALF3WT AirTAC Filter Regulator NPT3/8

The AirTAC GFR400C10ALF3WT AirTAC Filter Regulator NPT3/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$81.05 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR400C10ALF3WT AirTAC Filter Regulator NPT3/8

The GFR400C10ALF3WT is an AirTAC GFR400 filter regulator: one body that removes water and particulate from compressed air and holds downstream pressure steady. This configuration is built for low-pressure circuits, with a 3/8 in NPT port, the 5 um filter element (the finer of the two published grades), an automatic drain that empties the polycarbonate bowl without manual attention, and an embedded square gauge scaled in bar. Maximum inlet pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing. A mounting bracket is included with this code.

It is a genuine AirTAC part. The GFR line spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, a choice of differential-pressure, automatic or manual drains, 40 um or 5 um filtration, PT, G or NPT threads, gauge scales in MPa, psi or bar, and an optional reverse/check valve. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application before ordering.

GFR400C10ALF3WT AirTAC Filter Regulator NPT3/8 Technical Specifications

ModelGFR400C10ALF3WT AirTAC Filter Regulator NPT3/8
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR400C10ALF3WT AirTAC Filter Regulator NPT3/8

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the GFR400C10ALF3WT AirTAC Filter Regulator NPT3/8 Is Used

valve

Low-pressure clamping circuits

Holds a steady reduced pressure on pneumatic clamp and hold-down cylinders in woodworking and fixture lines, with the 5 um element helping protect downstream valve seats.

science

Coating and spray lines

Conditions the air feeding low-pressure spray and coating guns, where fine filtration and the automatic drain keep moisture and particulate out of the finish.

conveyor_belt

Packaging conveyor actuators

Regulates supply to sorting and packaging cylinders that run at reduced pressure, with the automatic drain handling condensate between shifts without operator attention.

Is the GFR400C10ALF3WT AirTAC Filter Regulator NPT3/8 the Right Unit?

Size 400 with a 3/8 in NPT port sits in the middle of the GFR range; step up to size 600 or down to 300 or 200 as your air demand dictates - we can check the published flow curves against your consumption if you send the figures. The 5 um element (code W) suits work where finer particulate matters; the 40 um element is the standard grade on other codes. The automatic drain suits unattended installations; manual and differential-pressure drains are available on other codes. This is the low-pressure (L) type, chosen where the working band sits below the standard regulator range - we confirm the exact adjustment span from the datasheet on request. The square gauge on this code is scaled in bar; MPa and psi scales, an external round gauge, PT or G threads and the reverse/check valve round out the order-time choices.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR400C10ALF3WT AirTAC Filter Regulator NPT3/8 FAQ

AirTAC publishes flow for the GFR series as curves, not as a single rated number, so there is no one figure we can quote honestly. Send us your line pressure and air consumption and we will confirm the sizing from the datasheet before you order.

The L in the code marks the low-pressure regulator type, used where the working band sits below the standard range; the W marks the 5 um element instead of the 40 um standard. Both are order-time choices - tell us your working pressure and air quality needs and we will confirm this is the right configuration.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR400C10ALF3WT AirTAC Filter Regulator NPT3/8

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C10ALF3WT and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.