The AirTAC GFR400C10ALJF2WT AirTAC Filter Regulator NPT3/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR400C10ALJF2WT is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This size 400 unit has a 3/8 in NPT port, a 5 um filter element (the finer of the two published grades), an automatic drain that ejects collected condensate without manual attention, and the low-pressure regulator type. A square pressure gauge with a psi scale is fitted, the bowl is polycarbonate (PC), and no mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR family is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 in, and with choices of drain type, filter grade, gauge scale, thread (PT standard, G and NPT to order) and bracket. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application.
| Model | GFR400C10ALJF2WT AirTAC Filter Regulator NPT3/8, 5 um |
|---|---|
| Series | GFR400 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · See datasheet · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-C1 (two-unit set) |
Filtered, regulated air to the clamping fixtures of a CNC machining cell, with the 5 um element helping keep spool valves and clamp cylinders clean.
Regulated low-pressure air to the sealing heads and grippers of a packaging conveyor, with the automatic drain handling condensate through long shifts.
Point-of-use air preparation ahead of a spray gun in a paint booth, where the 5 um element and a set regulated pressure support a consistent finish.
Choose the size and port step (200/300/400/600, 1/8 to 1 in) against the air demand of the line; this unit is the size 400, 3/8 in NPT step. Pick the drain: differential-pressure (default), automatic (as fitted here) or manual. Pick the element: 40 um standard or 5 um (code W) where finer filtration is needed - this unit carries the 5 um element. The L code makes this the low-pressure regulator type; its exact adjustment range is not published, so confirm it with us. Gauge scale can be MPa, psi or bar (psi fitted here), thread is PT as standard with G and NPT as order options, and a bracket can be added. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Send us your line pressure and air demand and we will confirm the flow and sizing from the datasheet on request.
The L in the code marks the low-pressure regulator type. Its exact adjustment range is not published in our data, so confirm the range with us before ordering. The unit otherwise follows the standard GFR specification, with a 1.0 MPa (145 psi) maximum inlet pressure and a -5 to 70 C working range.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.