AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR400C10ALNWTK AirTAC Filter Regulator, NPT3/8, 5 um

The AirTAC GFR400C10ALNWTK AirTAC Filter Regulator, NPT3/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$86.52 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR400C10ALNWTK AirTAC Filter Regulator, NPT3/8, 5 um

The GFR400C10ALNWTK is an AirTAC GFR400 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is built around a 3/8 in NPT port, a 5 um filter element (the finer of the two catalogue grades), an automatic drain that expels collected condensate without manual attention, and the low-pressure regulator type. No gauge is fitted (code N), a reverse/check valve is included, and a mounting bracket is included.

This is a genuine AirTAC part. The GFR series spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 in, and options for thread (PT standard; G and NPT to order), drain type, filter grade, gauge and scale, and check valve. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and any datasheet figure for your application before ordering.

GFR400C10ALNWTK AirTAC Filter Regulator, NPT3/8, 5 um Technical Specifications

ModelGFR400C10ALNWTK AirTAC Filter Regulator, NPT3/8, 5 um
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR400C10ALNWTK AirTAC Filter Regulator, NPT3/8, 5 um

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the GFR400C10ALNWTK AirTAC Filter Regulator, NPT3/8, 5 um Is Used

precision_manufacturing

CNC machine-tool clamping

Filtered, regulated air to pneumatic clamps and tool-change cylinders on a machining centre, with the 5 um element protecting fine pilot valves upstream of the actuators.

conveyor_belt

Conveyor diverting gates

Supplying diverters and stopper cylinders on a packaging conveyor, where the automatic drain keeps collected condensate off the line without daily manual checks.

science

Laboratory test rig

Low-pressure regulation for a bench test rig or pilot-plant skid running instrument air at reduced pressure, with the fitted check valve preventing backflow toward the supply side.

Is the GFR400C10ALNWTK AirTAC Filter Regulator, NPT3/8, 5 um the Right Unit?

Choose the size by port and required flow: size 400 with a 3/8 in NPT port sits in the middle of the GFR range (200/300/400/600). This unit already carries the 5 um element (code W) instead of the 40 um standard - pick 5 um where downstream equipment needs finer filtration, 40 um for general line protection. Drain options are differential-pressure (default), automatic (fitted here) and manual; automatic suits installations that are not checked daily. This is the low-pressure regulator type (code L); its exact adjustment range is not published in the catalogue, so confirm it with us before ordering. No gauge is fitted - a square or round gauge with an MPa, psi or bar scale can be specified instead. PT is the standard thread; G (BSPP) and NPT are catalogue options to order. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR400C10ALNWTK AirTAC Filter Regulator, NPT3/8, 5 um FAQ

AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number here. Tell us your working pressure and required flow and we will confirm sizing against the datasheet on request.

Yes. Code N means no gauge is fitted. The GFR series accepts an embedded square gauge or an optional external round gauge, with MPa, psi or bar scales; specify the gauge code when ordering. Since this unit is the low-pressure type, also confirm its adjustment range with us at the same time.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR400C10ALNWTK AirTAC Filter Regulator, NPT3/8, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C10ALNWTK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.