verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR400C10C3T AirTAC Filter Regulator NPT3/8, 40 um

The AirTAC GFR400C10C3T AirTAC Filter Regulator NPT3/8, 40 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$70.65 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR400C10C3T AirTAC Filter Regulator NPT3/8, 40 um

The AirTAC GFR400C10C3T is a size 400 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration has a 3/8 in NPT port, a 40 um standard filter element, a differential-pressure drain that bleeds collected condensate automatically whenever the pressure differential across the element is high enough, and a fitted round pressure gauge reading in bar. The standard regulator covers 0.15-0.9 MPa (20-130 psi) of adjustment, and maximum inlet pressure is 1.0 MPa (145 psi). Operating temperature is -5 to 70 C (non-freezing), and the polycarbonate bowl suits the 400 frame.

This is a genuine AirTAC part. The GFR family is published in sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 in, optional 5 um (code W) elements, automatic or manual drains, square or round gauges with MPa, psi or bar scales, and G (BSPP) or NPT threads in place of the PT standard. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application.

GFR400C10C3T AirTAC Filter Regulator NPT3/8, 40 um Technical Specifications

ModelGFR400C10C3T AirTAC Filter Regulator NPT3/8, 40 um
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR400C10C3T AirTAC Filter Regulator NPT3/8, 40 um

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the GFR400C10C3T AirTAC Filter Regulator NPT3/8, 40 um Is Used

factory

Stamping press pneumatic circuit

Point-of-use conditioning ahead of the press counterbalance and clamping cylinders: the 40 um element keeps scale and condensed water out of the valve stack while the regulator holds a steady set pressure for consistent die clamping.

conveyor_belt

Packaging line conveyor actuators

Mounted at the drop feeding stopper cylinders and pusher actuators on a carton packaging conveyor, giving the line a single body that cleans the air and holds the pressure the diverters were set up with.

engineering

Machine shop CNC air drop

Installed on the service drop feeding a CNC machining centre's air blast and tool-change circuit, where the differential-pressure drain handles condensate continuously and the bar gauge lets the setter verify set pressure at a glance.

Is the GFR400C10C3T AirTAC Filter Regulator NPT3/8, 40 um the Right Unit?

Size 400 with a 3/8 in port sits in the middle of the GFR range; step up to 600 or down to 300/200 depending on the flow your line needs, and confirm the step against the published flow curves before ordering. Drain choice is real: differential-pressure (this code) needs no attention during operation, automatic drains on a cycle, and manual drains (0.05-0.9 MPa adjustment range) suit intermittent duty. The 40 um element is standard; specify the W code for 5 um where finer particulate removal matters. This unit carries a round gauge reading in bar; square gauges and MPa or psi scales are catalogue options. Thread here is NPT; PT is the standard and G (BSPP) is also orderable as a specification option. A mounting bracket is included.

Flow is published as curves, not a single rating, so send us your application conditions and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR400C10C3T AirTAC Filter Regulator NPT3/8, 40 um FAQ

AirTAC publishes filter-regulator flow as curves rather than a single rated figure, so we do not quote a rated flow number for this unit. Send us your inlet pressure, set pressure and required flow, and we will confirm the sizing against the datasheet curves on request before you order.

Yes. Gauge scale is a decodable option in the GFR range: scale 1 reads MPa, scale 2 reads psi and scale 3 reads bar, so this C3 code carries the round gauge with the bar scale. Square embedded gauges and the other scales are catalogue specification options you can order instead.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR400C10C3T AirTAC Filter Regulator NPT3/8, 40 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C10C3T and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.