verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR400C10F2W AirTAC Filter Regulator 3/8 in PT, 5 um

The AirTAC GFR400C10F2W AirTAC Filter Regulator 3/8 in PT, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$70.02 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR400C10F2W AirTAC Filter Regulator 3/8 in PT, 5 um

The AirTAC GFR400C10F2W is a size-400 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration carries a 3/8 in PT port, a 5 um filter element (the finer of the two published grades), a differential-pressure drain that bleeds collected condensate automatically whenever the pressure differential across the element rises, a standard regulator with a 0.15-0.9 MPa (20-130 psi) setting range, and an embedded square gauge reading in psi. A mounting bracket is included.

This is a genuine AirTAC part from the GFR series, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drains, 40 um or 5 um filtration, MPa, psi or bar gauge scales, and PT, G or NPT threads. Flow figures for this series are published as curves rather than a single rating, so ask us and we will confirm the datasheet figures for your application on request.

GFR400C10F2W AirTAC Filter Regulator 3/8 in PT, 5 um Technical Specifications

ModelGFR400C10F2W AirTAC Filter Regulator 3/8 in PT, 5 um
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR400C10F2W AirTAC Filter Regulator 3/8 in PT, 5 um

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the GFR400C10F2W AirTAC Filter Regulator 3/8 in PT, 5 um Is Used

precision_manufacturing

CNC machining centre air supply

Feeds filtered, regulated air to the tool-clamp and chuck-actuation circuits of a CNC machining centre, where the 5 um element protects the clamping valve stack from water and swarf carried in shop air.

conveyor_belt

Packaging line carton sealer

Sits upstream of the cylinders and flap actuators on a carton-sealing machine, holding a steady working pressure so the taping head and box clamps cycle consistently through every shift.

factory

Bottling plant filler valves

Conditions the air feeding the fill-valve and capper actuators on a bottling line, keeping moisture and fine particulate out of the valve seats while the regulator pins the pressure the filler controls were set around.

Is the GFR400C10F2W AirTAC Filter Regulator 3/8 in PT, 5 um the Right Unit?

Size and port set the capacity envelope: GFR400 takes a 3/8 in port and sits above the 200/300 sizes and below the 600 in the published flow curves, so step up or down according to the air demand of the circuit rather than the port alone. The drain choice matters: differential-pressure (this unit) needs no operator attention but only purges when the element loads up, automatic drains on a cycle, and manual drains suit intermittent-duty installations where someone checks the bowl. Filtration is 40 um standard or 5 um with the W code - this unit is the 5 um version, the right call for directional valves, cylinders and instrumentation that tolerate less particulate. The gauge is the embedded square type; psi scale here, with MPa and bar scales available, and an external round gauge is an option. Thread is PT as standard with G and NPT as orderable options, and a bracket is included.

Because flow for the G-series is published only as curves and not as a single rated figure, we do not quote a number here - send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR400C10F2W AirTAC Filter Regulator 3/8 in PT, 5 um FAQ

AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number on the page. Tell us your line pressure, set pressure and air demand, and we will confirm the flow figures from the datasheet for this 3/8 in size-400 unit on request.

The W in the model code selects the 5 um filter grade; without it, GFR units ship with the 40 um standard element. The 5 um grade suits downstream directional valves, cylinders and instrumentation that need finer particulate removal, while 40 um remains the economical choice for general plant air.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR400C10F2W AirTAC Filter Regulator 3/8 in PT, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C10F2W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.