The AirTAC GFR400C10LJF1T AirTAC Filter Regulator 3/8 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR400C10LJF1T is an AirTAC GFR400 filter regulator: a 40 um filter and a pressure regulator combined in a single body, sized 400 with a 3/8 in NPT port. This low-pressure type unit carries a differential-pressure drain, a polycarbonate bowl, an embedded square gauge scaled in MPa, and no mounting bracket or reverse/check valve. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
It is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, and options that include manual or automatic drains, a 5 um filter element (code W), psi or bar gauge scales, an external round gauge, G or NPT threads and a mounting bracket. Flow is published as curves rather than a single rating, so ask us to confirm sizing and datasheet figures for your application.
| Model | GFR400C10LJF1T AirTAC Filter Regulator 3/8 in NPT |
|---|---|
| Series | GFR400 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · See datasheet · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-C1 (two-unit set) |
Feeds filtered, regulated air to the pneumatic clamps and swing cylinders on a machining fixture, holding a stable low set pressure while the 40 um element keeps scale and pipe debris out of the clamp valve seats.
Supplies the diverters, stoppers and pusher cylinders along a packaging conveyor with water- and particle-free air at a controlled pressure, with the differential-pressure drain bleeding collected condensate while the line runs.
Sits at branch take-off points on a factory air ring main, giving each downstream station its own filtered, regulated supply so one station's pressure adjustment does not disturb its neighbours.
Within the GFR line you choose size (200/300/400/600) and port (1/8 to 1 in) to match the flow your circuit needs - step up a size for higher flow. Drain comes as differential-pressure (this model), automatic (A) or manual (M); filtration is 40 um standard or 5 um with code W; the gauge can be the embedded square type in MPa, psi or bar scales, or an external round gauge; thread is PT as standard with G and NPT as order options; a bracket is optional and this unit is configured without one. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow and the full datasheet figures for this size 400, 3/8 in NPT unit on request.
The L code identifies the low-pressure variant of the GFR regulator, as opposed to the standard type. The exact adjustment range for this variant is not published on our sheet, so tell us your set pressure and we will confirm suitability on request before you order.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.