verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR400C10MC1TK AirTAC Filter Regulator NPT 3/8 in

The AirTAC GFR400C10MC1TK AirTAC Filter Regulator NPT 3/8 in is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$81.71 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR400C10MC1TK AirTAC Filter Regulator NPT 3/8 in

The AirTAC GFR400C10MC1TK is a size 400 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration has a 3/8 in NPT port, a manual drain bowl in polycarbonate (PC), a standard 40 um filter element, a fitted reverse/check valve, an included mounting bracket, and a round MPa pressure gauge (an embedded square gauge is the standard fitting, with an external round gauge available as the option on this unit). The regulator adjusts from 0.05 to 0.9 MPa (7-130 psi), and maximum inlet pressure is 1.0 MPa (145 psi). Operating temperature is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GFR family is published in sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 in, and with choices of drain type, 40 um or 5 um (W) filtration, gauge type and scale, thread (PT standard; G and NPT to order), bracket and reverse valve. Flow is published as curves rather than a single rating, so ask us and we will confirm the flow and datasheet figures for your application on request.

GFR400C10MC1TK AirTAC Filter Regulator NPT 3/8 in Technical Specifications

ModelGFR400C10MC1TK AirTAC Filter Regulator NPT 3/8 in
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR400C10MC1TK AirTAC Filter Regulator NPT 3/8 in

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the GFR400C10MC1TK AirTAC Filter Regulator NPT 3/8 in Is Used

factory

Packaging machine air preparation

Feeding clean, regulated air to the cylinders and actuators on a carton-forming and sealing line, with the manual drain serviced during shift changeovers.

conveyor_belt

Conveyor gate and diverter control

Regulating supply pressure to pop-up diverters and stop gates on a distribution conveyor, with the check valve holding the downstream circuit if supply drops.

science

Lab pneumatic bench supply

Conditioning and setting a stable pressure at a test-bench manifold where instruments and air cylinders need filtered air at a fixed setpoint.

Is the GFR400C10MC1TK AirTAC Filter Regulator NPT 3/8 in the Right Unit?

Size 400 with a 3/8 in NPT port suits lines where the required flow sits above the 300 frame; step up or down through 200/300/400/600 to match your port and curve. The manual drain on this unit means an operator opens the bowl drain at intervals - choose the automatic (A) or differential-pressure (blank) drain instead if the unit is hard to reach. The 40 um element is the standard grade; specify W for 5 um where finer particulate removal is needed. The fitted round gauge reads in MPa (scales in psi or bar are order options), and the K code means a reverse/check valve is fitted to hold downstream pressure. Thread here is NPT; PT is the catalogue standard with G (BSPP) available to order, and the mounting bracket is included.

Because flow is published as curves and not as a single rated figure, send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR400C10MC1TK AirTAC Filter Regulator NPT 3/8 in FAQ

AirTAC publishes G-series flow as curves, not as a single rated number, so we do not quote a l/min, m3/h or SCFM figure. Tell us your application and we will confirm the flow and full datasheet figures for this unit on request.

The M code means the bowl drain is opened by hand at intervals to remove collected condensate - simple and reliable where the unit is accessible. If the unit will be mounted where it cannot easily be reached, order the same GFR400 size with an automatic (A) or differential-pressure (blank) drain instead.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR400C10MC1TK AirTAC Filter Regulator NPT 3/8 in

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C10MC1TK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.