The AirTAC GFR400C10MJF1T AirTAC Filter Regulator NPT3/8, Manual Drain is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR400C10MJF1T is an AirTAC GFR400 filter regulator: it removes water and particulate from compressed air and sets downstream pressure in a single body. This size 400 unit is threaded 3/8 in NPT, carries a 40 um filter element, and uses a manual drain, so the bowl is emptied by opening its drain valve during routine checks. The standard regulator covers 0.05-0.9 MPa (7-130 psi) and the fitted embedded square gauge reads outlet pressure in MPa.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, optional 5 um filtration (code W), automatic or differential-pressure drains, psi or bar gauge scales, and G (BSPP) or NPT threads as order options. Flow is published as curves rather than a single rating, so ask us to confirm figures from the datasheet for your application.
| Model | GFR400C10MJF1T AirTAC Filter Regulator NPT3/8, Manual Drain |
|---|---|
| Series | GFR400 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · See datasheet · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-C1 (two-unit set) |
Filter and regulate the shop-air feed to a CNC machine's pneumatic circuit: clean, moisture-reduced air at a set pressure for tool-change cylinders and clamping actuation, with the MPa gauge giving operators a local pressure reference.
Condition the air feeding conveyor stoppers, pushers and divert gates on a packaging line, holding a stable set pressure so sorting and stopping actions repeat consistently through the shift.
Install at the take-off point where a factory ring main drops air to an assembly cell, filtering scale, rust and condensed water out of the distributed supply and regulating it to the pressure the cell's actuators were set up for.
Size 400 with a 3/8 in NPT port suits lines where the supply connection is 3/8 in; step up to size 600 or down to 300/200 if your piping and expected flow demand it. This configuration has a manual drain, which is the right choice when someone is already at the machine regularly; choose the automatic drain version where the unit is hard to reach. Filtration is the 40 um standard element; specify the 5 um (W) option only where downstream equipment needs finer air. The fitted square gauge reads in MPa, and psi or bar scales are available. Thread here is NPT; PT is the AirTAC standard and G (BSPP) can be ordered. No mounting bracket is included with this code (J).
Because AirTAC publishes flow only as curves and not as a single rated figure, we do not quote a flow number here. Send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR400 as performance curves rather than a single rated figure, so we do not quote a flow number. Tell us your application and we will confirm the relevant flow data from the datasheet on request before you order.
The M in the code GFR400C10MJF1T specifies a manual drain: condensed water collects in the polycarbonate bowl and is released by opening the drain valve during routine checks. If the unit will be mounted where regular attention is impractical, the same filter regulator is available with an automatic drain or the differential-pressure drain as the order option.