The AirTAC GFR400C10MJF1WTK AirTAC Filter Regulator NPT3/8 5um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR400C10MJF1WTK is a size 400 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration is built with a 3/8 in NPT port, a fine 5 um filter element, a manual drain for the bowl, an embedded square pressure gauge scaled in MPa, and a reverse (check) valve fitted, and it mounts without a bracket. The standard regulator covers an adjustment range of 0.05-0.9 MPa (7-130 psi), with a maximum inlet pressure of 1.0 MPa (145 psi) and an operating temperature of -5 to 70 C (non-freezing).
This is a genuine AirTAC part from the GFR filter-regulator family, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and options including automatic, manual or differential-pressure drains, 40 um or 5 um filtration, square or round gauges with MPa, psi or bar scales, and PT, G or NPT threads. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering.
| Model | GFR400C10MJF1WTK AirTAC Filter Regulator NPT3/8 5um |
|---|---|
| Series | GFR400 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · See datasheet · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-C1 (two-unit set) |
Cleaning and regulating the shop-air feed to a machining centre's tool-changer and clamping circuits, where the 5 um element protects precision valves and the manual drain is emptied during shift checks.
Conditioning the air feeding conveyor stoppers and pusher cylinders on a packaging line, with the regulator set to the actuator's rated pressure and the check valve holding the circuit if the main supply dips.
A filtered, regulated drop feeding air-operated instruments and small process valves in a factory utility ring, where the MPa-scale gauge lets technicians verify set pressure at a glance.
Size 400 with a 3/8 in NPT port suits lines where moderate-to-high air consumption meets a 3/8 in supply main; step up or down a size if your piping or expected flow differs. The 5 um element (code W) is the finer of the two published grades (40 um standard, 5 um optional) - choose it where downstream valves and instruments are sensitive to finer particles. The manual drain means an operator opens the drain periodically instead of relying on an automatic or differential-pressure drain, which suits attended installations. The square MPa gauge reads outlet pressure directly, and the fitted check valve holds downstream pressure if the upstream supply drops. PT is the standard thread for the series; G (BSPP) and NPT are catalogue options ordered by suffix, as here. Flow is published as curves, not a single rated figure, so send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for this series as curves, not as a single rated figure, so we do not quote a l/min or SCFM number. Send us your application details and we will confirm the flow and sizing figures from the datasheet on request.
The M in the code specifies a manual drain: an operator opens the drain to expel collected water. The GFR400 series is also catalogued with automatic (A) and differential-pressure (blank) drains, so if you prefer hands-off draining, ask us for the equivalent model with that drain option.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.