verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR400C10MJF2K AirTAC Filter Regulator PT3/8, Manual Drain

The AirTAC GFR400C10MJF2K AirTAC Filter Regulator PT3/8, Manual Drain is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$80.12 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR400C10MJF2K AirTAC Filter Regulator PT3/8, Manual Drain

The GFR400C10MJF2K is an AirTAC GFR400 filter regulator: it removes water and particulate from compressed air and holds downstream pressure steady, in a single body. This configuration is the 400 size with a 3/8 in PT port, a manual drain on the polycarbonate bowl, a 40 um standard filter element, an embedded square gauge scaled in psi, a reverse (check) valve fitted, and no mounting bracket (code J). Maximum inlet pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing. The standard regulator adjusts from 0.05 to 0.9 MPa (7-130 psi) with this manual-drain version.

This is a genuine AirTAC part. The GFR filter-regulator family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, drain choices (differential-pressure, automatic or manual), 40 um standard or 5 um (W) filtration, gauge and thread options (PT standard; G and NPT are order options). Flow is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for your application.

GFR400C10MJF2K AirTAC Filter Regulator PT3/8, Manual Drain Technical Specifications

ModelGFR400C10MJF2K AirTAC Filter Regulator PT3/8, Manual Drain
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR400C10MJF2K AirTAC Filter Regulator PT3/8, Manual Drain

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the GFR400C10MJF2K AirTAC Filter Regulator PT3/8, Manual Drain Is Used

factory

CNC machining cell air supply

Point-of-use conditioning on the air drop feeding clamps, tool-changer cylinders and chip-ejection actuators on a CNC machining centre: water and swarf-carrying moisture are stripped out and the regulator holds a steady setting so clamping force stays repeatable across the shift. The manual drain suits a cell where an operator already walks the machine daily.

conveyor_belt

Packaging line actuation feed

Conditioned air for the carton-sealing and case-erector cylinders along a packaging conveyor line. The 40 um element protects the solenoid valves and cylinder seals from water and particulate, the check valve holds the set pressure if the upstream supply dips, and the psi-scaled square gauge lets line staff verify the setting at a glance.

valve

Process valve actuation skid

Air preparation on a skid actuating solenoid-controlled process valves in a water-treatment or chemical-dosing plant. The filter-regulator delivers clean, regulated air to the positioners and actuators, the manual drain is serviced during scheduled rounds, and the 3/8 in PT port ties into the skid's instrument-air tubing.

Is the GFR400C10MJF2K AirTAC Filter Regulator PT3/8, Manual Drain the Right Unit?

Step up or down the size/port ladder (200, 300, 400, 600) to match the pipe and the air demand of the machine being fed - the 400 size with its 3/8 in PT port sits in the mid-range of the family. Choose the drain to suit access: this unit has a manual drain (M), which you operate by hand; automatic (A) and differential-pressure (blank) versions are available if the bowl cannot be reached easily. Filtration is the 40 um standard element; specify W for the 5 um grade where downstream equipment needs finer air. The fitted square gauge reads in psi (scale 2); MPa and bar scales and an external round gauge are alternatives. Thread is PT as standard, with G (BSPP) and NPT available to order; this code carries no mounting bracket.

Because flow is published as curves and not as a single rated number, we do not quote a flow figure here. Send us your application details and we will confirm sizing against the datasheet curves before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR400C10MJF2K AirTAC Filter Regulator PT3/8, Manual Drain FAQ

AirTAC publishes flow for the GFR series as curves, not as a single rated number, so we do not state a flow figure on this page. Tell us your application - the machine, its pressure setting and its air demand - and we will confirm the relevant datasheet curve and check the sizing for you before you order.

This unit has code M, so accumulated condensate is drained from the bowl by hand - a good choice where the unit is accessible during daily checks. The family also offers automatic drain (A) and differential-pressure drain (blank, the default). Note that with the manual-drain version the regulator adjustment range is 0.05-0.9 MPa (7-130 psi); the automatic and differential-pressure versions adjust from 0.15-0.9 MPa (20-130 psi).

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR400C10MJF2K AirTAC Filter Regulator PT3/8, Manual Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C10MJF2K and will confirm price, stock and lead time — usually within 7-8 hours.