verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR400C10MJNTK AirTAC Filter Regulator, NPT3/8, Manual Drain

The AirTAC GFR400C10MJNTK AirTAC Filter Regulator, NPT3/8, Manual Drain is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$74.82 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR400C10MJNTK AirTAC Filter Regulator, NPT3/8, Manual Drain

The GFR400C10MJNTK is an AirTAC GFR400 filter regulator: water and particulate filtration plus pressure regulation combined in one body. This configuration has a 3/8 in NPT port, a manual-drain bowl, the standard 40 um filter element and an integrated reverse-flow (check) valve, and it is supplied without a gauge and without a mounting bracket. Outlet pressure is set anywhere in the 0.05-0.9 MPa (7-130 psi) adjustment range; maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part from the G-series air-treatment line, which spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, a choice of G (BSPP), NPT or PT thread, automatic, manual or differential-pressure drains, an optional 5 um element and gauge options. Flow for this unit is published as a curve rather than a single rated figure, so ask us to confirm the datasheet and check the sizing for your application.

GFR400C10MJNTK AirTAC Filter Regulator, NPT3/8, Manual Drain Technical Specifications

ModelGFR400C10MJNTK AirTAC Filter Regulator, NPT3/8, Manual Drain
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR400C10MJNTK AirTAC Filter Regulator, NPT3/8, Manual Drain

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the GFR400C10MJNTK AirTAC Filter Regulator, NPT3/8, Manual Drain Is Used

factory

Bottling line actuator supply

Clean, regulated air for the gripper, capper and filler cylinders on a bottling line, with the manual drain bled during scheduled changeover checks.

precision_manufacturing

CNC tool-change circuit

Conditioned air at a fixed setpoint for the tool changer and workpiece clamps on a machining centre, with the check valve holding the downstream circuit if supply pressure dips.

conveyor_belt

Conveyor diverters and stops

Filtered, regulated air for the diverter, stopper and pusher cylinders on a sorting conveyor, keeping moisture and debris out of the directional valves.

Is the GFR400C10MJNTK AirTAC Filter Regulator, NPT3/8, Manual Drain the Right Unit?

Size 400 with a 3/8 in NPT port suits circuits plumbed at 3/8 in; if your flow demand or piping differs, step up or down a size and we will confirm the flow curve against your requirement before you order. The manual drain needs an operator to bleed the bowl, so choose it where the unit is checked routinely; the automatic or differential-pressure drain variants suit unattended installations. The standard 40 um element protects most actuators and valves, while the W variant gives 5 um filtration for finer downstream needs. This unit is supplied without a gauge - a gauge with an MPa, psi or bar scale can be added if you want a local setpoint display - and without a mounting bracket. The thread here is NPT; PT is the standard and G (BSPP) is also an order option.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR400C10MJNTK AirTAC Filter Regulator, NPT3/8, Manual Drain FAQ

Flow for the GFR400 is published as a curve, not a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the datasheet curve and check the sizing against your air demand before you order.

This model carries the N gauge code, so no gauge is fitted. Because it is a regulator, a gauge can be added - choose an embedded square gauge or an external round gauge with an MPa, psi or bar scale - so specify the gauge option when ordering if you want a local setpoint display.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR400C10MJNTK AirTAC Filter Regulator, NPT3/8, Manual Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C10MJNTK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.