The AirTAC GFR400C15AC2G AirTAC Filter Regulator G1/2, Auto Drain is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR400C15AC2G is a size 400 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration has a G1/2 (BSPP) port, an automatic drain that expels collected condensate without manual attention, a 40 um standard filter element, and a round pressure gauge reading in psi. Maximum inlet pressure is 1.0 MPa (145 psi), the standard regulation range is 0.15-0.9 MPa (20-130 psi), and the operating temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR series is available in sizes 200, 300, 400 and 600 with a choice of ports, drain types (differential-pressure, automatic or manual), 40 um or 5 um (W) filtration, gauge styles and scales, and PT, G or NPT threads. Flow is published as curves rather than a single rating, so we confirm the datasheet figures for your application on request.
| Model | GFR400C15AC2G AirTAC Filter Regulator G1/2, Auto Drain |
|---|---|
| Series | GFR400 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · See datasheet · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-C1 (two-unit set) |
Clean, regulated air for carton sealers and wrap stations, with the automatic drain handling condensate on lines that run unattended through shifts.
Feeds conveyor stopper and gate cylinders with filtered air held at a stable setpoint, protecting seals from water and debris carryover.
A single-body filter regulator at the machine inlet, with the psi gauge giving operators a local reading of the circuit pressure.
Size 400 with a 1/2 in port suits lines where larger piping and higher flow demand apply; step down to 200 or 300 for smaller circuits and up to 600 for the largest ports. Choose the automatic drain on this unit where condensate must be removed without operator attention; differential-pressure and manual drains are also available in the series. The 40 um element is the standard grade; specify 5 um (code W) where finer filtration is needed. The fitted round gauge reads in psi; embedded square gauges and MPa or bar scales are alternatives. G (BSPP) thread is specified here, with PT and NPT orderable. A mounting bracket is included.
Because flow is published as curves rather than a single rated figure, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Tell us your application and we will confirm the relevant datasheet flow figures on request before you order.
The automatic drain expels collected condensate by itself, which suits installations that are not checked daily. The series also offers a differential-pressure drain (the default) and a manual drain (code M) if you prefer those behaviours.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.