The AirTAC GFR400C15AF2 AirTAC Filter Regulator PT1/2, 40 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR400C15AF2 is an AirTAC GFR400 filter regulator: water and particulate filtration plus pressure regulation combined in one body. This size 400 unit has a PT1/2 port, a 40 um filter element, an automatic drain that expels collected condensate without manual attention, and an embedded square gauge reading in psi. The standard regulator covers an adjustment range of 0.15-0.9 MPa (20-130 psi), maximum inlet pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing). A mounting bracket is included, and the bowl at this size is polycarbonate.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, and options include a 5 um element (code W), manual or differential-pressure drain, G (BSPP) or NPT thread, alternative gauge scales in MPa or bar, and an external round gauge. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application.
| Model | GFR400C15AF2 AirTAC Filter Regulator PT1/2, 40 um |
|---|---|
| Series | GFR400 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · See datasheet · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-C1 (two-unit set) |
Filtered, pressure-regulated air supplied to spray guns and air-assisted applicators on a paint line, with the automatic drain clearing collected condensate between shifts.
Regulated supply for the pneumatic cylinders and grippers that fold and seal cartons on a packaging conveyor, holding actuator pressure steady through the run.
Point-of-use conditioning ahead of a machining centre's tool-change cylinder and air blast, removing water and particulate before the machine's own valves.
Choose the size and port against the air demand of the circuit: 400 with a PT1/2 port sits in the middle of the GFR range, one step up from 300 and one below 600. Decide the drain: this unit is automatic, while manual and differential-pressure drains are orderable alternatives. The 40 um element is standard; specify 5 um (code W) where finer particulate removal matters. The embedded square gauge here reads psi; MPa and bar scales are available. Thread is PT as standard, with G (BSPP) and NPT as order options, and a bracket is included. Because flow is published as curves rather than a single rating, send us your air demand and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR400 as curves rather than a single rated figure, so we do not quote a number here. Send us your air demand and operating pressure and we will confirm the flow from the datasheet on request.
The A in the code means the bowl expels collected condensate automatically, without anyone opening the drain. Manual and differential-pressure drain versions are available in the same size if your installation prefers them - just ask when ordering.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.