verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR600C25AJC2 AirTAC Filter Regulator 1 in PT Auto Drain

The AirTAC GFR600C25AJC2 AirTAC Filter Regulator 1 in PT Auto Drain is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$123.21 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR600C25AJC2 AirTAC Filter Regulator 1 in PT Auto Drain

The AirTAC GFR600C25AJC2 is a size-600 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration carries a 1 in PT port, an automatic drain that purges collected condensate without manual attention, a 40 um standard filter element, and a round pressure gauge reading in psi. The regulator is the standard type with a 0.15-0.9 MPa (20-130 psi) adjustment range, the bowl is aluminium alloy at this size, and no mounting bracket or reverse/check valve is fitted.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and options including manual or differential-pressure drains, a 5 um (W) element, square embedded or round external gauges with MPa, psi or bar scales, G or NPT threads, and brackets. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application.

GFR600C25AJC2 AirTAC Filter Regulator 1 in PT Auto Drain Technical Specifications

ModelGFR600C25AJC2 AirTAC Filter Regulator 1 in PT Auto Drain
SeriesGFR600 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR600C25AJC2 AirTAC Filter Regulator 1 in PT Auto Drain

GFR600G-series filter regulator, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · See datasheet · 40 µm
One size downGFR400
Add lubricationGFC600-C2 (two-unit set)

Where the GFR600C25AJC2 AirTAC Filter Regulator 1 in PT Auto Drain Is Used

factory

Automotive paint shop air drops

Placed at the drop to a spray booth, the unit filters water and scale out of the shop air line and holds a steady regulated pressure to the guns, with the automatic drain handling condensate between shifts.

conveyor_belt

Packaging line carton sealing

On a carton taper or case sealer fed from a plant air ring main, the 1 in filter regulator cleans the incoming air and keeps cylinder and actuator pressure stable through the whole production run.

precision_manufacturing

CNC machining centre air supply

Installed ahead of a machining centre's air preparation inlet, it strips moisture and particulate from the mill's compressed air feed and regulates it to the pressure the machine builder specifies.

Is the GFR600C25AJC2 AirTAC Filter Regulator 1 in PT Auto Drain the Right Unit?

Start with the port and size step: size 600 with a 1 in PT port is the largest GFR step, so match it against the air demand of the circuit - and because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering. Choose the drain to suit access: automatic (as here) suits unmanned or hard-to-reach installations, manual suits attended points, and differential-pressure is the default. Filter grade is 40 um standard or 5 um with the W code; gauge scale is MPa, psi or bar; thread is PT as standard with G (BSPP) and NPT as order options; a bracket is optional and this code omits it.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR600C25AJC2 AirTAC Filter Regulator 1 in PT Auto Drain FAQ

AirTAC publishes GFR flow as performance curves rather than a single rated figure, so we do not quote a number here. Tell us your inlet pressure and required downstream flow and we will confirm the sizing from the datasheet on request before you order.

The A in the code fits an automatic drain, which discharges collected condensate from the aluminium alloy bowl without anyone opening it - useful for unattended or elevated installations. The same GFR600 size is also available with a manual drain or the differential-pressure default, and the filter element can be specified as 5 um (code W) instead of the 40 um standard fitted here.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR600C25AJC2 AirTAC Filter Regulator 1 in PT Auto Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR600C25AJC2 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.