AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR600C25AJF2 AirTAC Filter Regulator PT1 in, Auto Drain

The AirTAC GFR600C25AJF2 AirTAC Filter Regulator PT1 in, Auto Drain is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$123.18 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR600C25AJF2 AirTAC Filter Regulator PT1 in, Auto Drain

The AirTAC GFR600C25AJF2 is a size-600 filter regulator that combines water and particulate removal with pressure regulation in a single body. This configuration is built with a 1 in PT port, an automatic drain that expels collected condensate without manual attention, a 40 um standard filter element, and an embedded square gauge reading in psi. The standard regulator covers an adjustment range of 0.15-0.9 MPa (20-130 psi), and the unit handles a maximum inlet pressure of 1.0 MPa (145 psi) at temperatures from -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GFR family is available in sizes 200, 300, 400 and 600 with a choice of ports, drain types (differential-pressure, automatic or manual), filter grades (40 um standard, 5 um optional), gauge scales (MPa, psi or bar) and G or NPT thread options. Flow is published as curves rather than a single rated figure, so we confirm flow and datasheet details on request before you order.

GFR600C25AJF2 AirTAC Filter Regulator PT1 in, Auto Drain Technical Specifications

ModelGFR600C25AJF2 AirTAC Filter Regulator PT1 in, Auto Drain
SeriesGFR600 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR600C25AJF2 AirTAC Filter Regulator PT1 in, Auto Drain

GFR600G-series filter regulator, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · See datasheet · 40 µm
One size downGFR400
Add lubricationGFC600-C2 (two-unit set)

Where the GFR600C25AJF2 AirTAC Filter Regulator PT1 in, Auto Drain Is Used

factory

Plant air main conditioning

Installed at the drop from a large compressed-air ring main to condition the supply feeding a production hall, removing water and particulate while holding a set downstream pressure.

settings_input_component

Automated assembly line supply

Feeding a bank of pneumatic actuators and air cylinders on an automated assembly line, where the automatic drain keeps condensate out of the circuit without daily operator attention.

conveyor_belt

Conveyor drive air preparation

Preparing air for conveyor drive cylinders and gate actuators on a packaging or material-handling conveyor, with the psi gauge letting maintenance staff verify the set pressure at a glance.

Is the GFR600C25AJF2 AirTAC Filter Regulator PT1 in, Auto Drain the Right Unit?

Sizing a GFR600 starts with the port and flow step: size 600 with a 1 in PT port is the largest step in the range, so match it against the air demand of the line rather than assuming a rated figure - flow is published as curves, and we will confirm sizing against your application on request. This unit's automatic drain suits unattended installations; if you prefer manual intervention or a differential-pressure drain, other GFR codes cover those choices. The 40 um element is the standard grade; a 5 um element (code W) is available where finer filtration is needed. The embedded square gauge here reads in psi, with MPa or bar scales and an external round gauge as alternatives. PT is the standard thread, with G (BSPP) and NPT as order options, and this code omits the mounting bracket.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR600C25AJF2 AirTAC Filter Regulator PT1 in, Auto Drain FAQ

AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a rated flow number. Send us your air demand and line conditions and we will confirm the sizing against the datasheet curves on request before you order.

The A in the code GFR600C25AJF2 specifies an automatic drain, which expels collected condensate from the bowl without manual attention - useful for unattended or hard-to-reach installations. GFR filter regulators are also available with a manual drain (code M) or the differential-pressure drain (blank), as separate model codes.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR600C25AJF2 AirTAC Filter Regulator PT1 in, Auto Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR600C25AJF2 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.