verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR600C25ALC1TK AirTAC Filter Regulator NPT1 Low-Pressure

The AirTAC GFR600C25ALC1TK AirTAC Filter Regulator NPT1 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$136.10 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR600C25ALC1TK AirTAC Filter Regulator NPT1 Low-Pressure

The AirTAC GFR600C25ALC1TK is a size-600 filter regulator: it removes water and particulate from compressed air and holds a steady downstream pressure in one body, so no separate filter and regulator pair is needed. This configuration is the low-pressure type with a 1 in NPT1 port, an automatic drain that ejects collected condensate without manual attention, a 40 um standard filter element, and a metal bowl (size 600 bowls are aluminium alloy). It ships as coded with a round external MPa gauge, a reverse/check valve fitted, and the mounting bracket included. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GFR family is published in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and with choices of thread (PT standard; G and NPT as order options), drain type (differential-pressure, automatic or manual), filter grade (40 um standard, 5 um with code W), gauge style and scale, and reverse valve. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and flow data for your application on request.

GFR600C25ALC1TK AirTAC Filter Regulator NPT1 Low-Pressure Technical Specifications

ModelGFR600C25ALC1TK AirTAC Filter Regulator NPT1 Low-Pressure
SeriesGFR600 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR600C25ALC1TK AirTAC Filter Regulator NPT1 Low-Pressure

GFR600G-series filter regulator, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · See datasheet · 40 µm
One size downGFR400
Add lubricationGFC600-C2 (two-unit set)

Where the GFR600C25ALC1TK AirTAC Filter Regulator NPT1 Low-Pressure Is Used

factory

Textile mill air rings and low-pressure jets

Weaving and spinning lines that run air nozzles and jets at reduced setpoints use the low-pressure GFR600 to clean the supply of water and lint-scale particulate while holding a stable, gentle pressure at the frame.

science

Automotive paint booth supply drops

At a spray-booth air drop, the unit strips water and 40 um particulate ahead of the regulator section so guns and air motors see clean air at a steady low setpoint, with the automatic drain clearing condensate between shifts.

conveyor_belt

Bottling line conveyor and gating actuators

On a bottling hall conveyor section, cylinder-driven gates and pushers need clean air at a consistent low pressure; the 1 in port feeds the whole section and the check valve holds the circuit if the main supply dips.

Is the GFR600C25ALC1TK AirTAC Filter Regulator NPT1 Low-Pressure the Right Unit?

Start with the size and port: this is the largest GFR frame (600) with a 1 in port, matched to lines with high air demand; smaller frames (200/300/400) cover lighter duties. Because this is the low-pressure type (code L), it suits circuits regulated well below standard mains pressure - confirm the setpoint range for your application with us before ordering. The automatic drain (code A) suits unattended or hard-to-reach installations; manual and differential-pressure drains are the alternatives in the family. The 40 um element is the standard grade; specify W for the 5 um option if downstream equipment needs finer filtration.

Other decodable choices: the round gauge here reads in MPa (scales 1/2/3 = MPa/psi/bar); the K code means a reverse/check valve is fitted to hold downstream pressure if the supply drops; the T code gives NPT thread (PT is the AirTAC standard, G/BSPP is also available); and the bracket is included. Flow is published as curves, not a single rating, so please ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR600C25ALC1TK AirTAC Filter Regulator NPT1 Low-Pressure FAQ

AirTAC publishes G-series flow as curves rather than a single rated figure, so we do not quote a rated flow, Cv or SCFM number for this unit. Ask us to confirm the datasheet and flow curves for the GFR600 at your operating conditions and we will send them before you order.

The A code fits the automatic drain: the bowl ejects collected condensate on its own, which suits unattended or hard-to-reach installations where a manual or differential-pressure drain would be neglected. The K code means a reverse/check valve is fitted, holding downstream pressure if the upstream supply is lost. This unit also carries the L code, so it is the low-pressure regulator type - confirm the setpoint range for your circuit with us.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR600C25ALC1TK AirTAC Filter Regulator NPT1 Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR600C25ALC1TK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.