verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR600C25C2TK AirTAC Filter Regulator 1 in NPT

The AirTAC GFR600C25C2TK AirTAC Filter Regulator 1 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$125.69 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR600C25C2TK AirTAC Filter Regulator 1 in NPT

The AirTAC GFR600C25C2TK is a size-600 filter regulator: it removes water and particulate from compressed air and sets downstream pressure in a single body. This configuration carries a 1 in NPT port, the standard 40 um filter element, a differential-pressure drain that bleeds collected condensate automatically whenever the pressure drop across the element rises, and a metal bowl (size 600 bowls are aluminium alloy). The regulator is the standard type with a 0.15-0.9 MPa (20-130 psi) setting range, a round external gauge reading in psi is fitted, and a reverse/check valve holds the downstream setting if upstream supply is interrupted. A mounting bracket is included.

This is a genuine AirTAC part from the GFR series, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in and PT, G (BSPP) or NPT threads to order. Drain types (differential-pressure, automatic or manual), a 5 um element (code W), gauge scale and low-pressure variants are available across the range. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.

GFR600C25C2TK AirTAC Filter Regulator 1 in NPT Technical Specifications

ModelGFR600C25C2TK AirTAC Filter Regulator 1 in NPT
SeriesGFR600 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR600C25C2TK AirTAC Filter Regulator 1 in NPT

GFR600G-series filter regulator, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · See datasheet · 40 µm
One size downGFR400
Add lubricationGFC600-C2 (two-unit set)

Where the GFR600C25C2TK AirTAC Filter Regulator 1 in NPT Is Used

factory

Plant air main conditioning

Installed at the take-off from a factory compressed-air ring main, it filters bulk water and pipe scale from the 1 in supply line and holds a steady header pressure for the whole work area.

conveyor_belt

Packaging line actuation

Feeding the valve stack on a carton-forming and conveyor section, it delivers cleaned air at a fixed setting so cylinders and grippers repeat the same stroke behaviour shift after shift.

local_shipping

Truck and trailer service bay

Supplying test benches and impact tools in a heavy-vehicle service bay, it removes moisture from the shop supply and lets the technician set and read a stable test pressure on the psi gauge.

Is the GFR600C25C2TK AirTAC Filter Regulator 1 in NPT the Right Unit?

Start with the port: this unit is the 1 in NPT version of the size-600 body, the largest step in the GFR range, so match it to your main line size and let the published flow curves - not a single rated figure - decide if a smaller size would do. The 40 um element suits general plant air; specify the W option if you need 5 um. The differential-pressure drain on this model needs no timer or operator attention, but if your line sees low and intermittent flow, an automatic or manual drain variant may suit better. The fitted round gauge reads in psi; square embedded gauges and MPa or bar scales are the other catalogue choices. PT is the standard thread and G (BSPP) or NPT are order options - this unit is specified with NPT. A bracket is included; a reverse/check valve (K) is fitted. Before ordering, send us your flow and pressure requirements and we will confirm sizing against the datasheet curves.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR600C25C2TK AirTAC Filter Regulator 1 in NPT FAQ

AirTAC publishes flow for the GFR series as curves, not as a single rated number, so we do not quote a figure here. Tell us your working pressure, setting pressure and expected air demand, and we will confirm the flow from the datasheet curve for this 1 in NPT size-600 unit before you order.

This model's differential-pressure drain opens to discharge collected condensate automatically when the pressure drop across the 40 um element rises as the bowl fills - no operator action or timer is needed. If your air demand is very low or intermittent, the automatic (code A) or manual (code M) drain variants are the catalogue alternatives; ask us which suits your duty cycle.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR600C25C2TK AirTAC Filter Regulator 1 in NPT

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR600C25C2TK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.