verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR600C25F2TK AirTAC Filter Regulator 1 in NPT

The AirTAC GFR600C25F2TK AirTAC Filter Regulator 1 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$125.67 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR600C25F2TK AirTAC Filter Regulator 1 in NPT

The GFR600C25F2TK is an AirTAC GFR-series filter regulator: one body that removes water and particulate from compressed air and then regulates downstream pressure. This size 600 unit carries a 1 in NPT port, a 40 um standard filtration grade, and a differential-pressure drain that bleeds collected condensate automatically whenever the pressure differential across the bowl is high enough. The metal bowl (aluminium alloy at size 600) suits demanding plant environments, a square pressure gauge with a psi scale is fitted for direct setpoint reading, a reverse/check valve holds downstream pressure when the supply is lost, and a mounting bracket is included.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, optional 5 um filtration (code W), automatic or manual drains, G or NPT thread options, and gauge or no-gauge variants. Rated flow is published as curves rather than a single figure, so ask us to confirm sizing and any datasheet figure against your application before ordering.

GFR600C25F2TK AirTAC Filter Regulator 1 in NPT Technical Specifications

ModelGFR600C25F2TK AirTAC Filter Regulator 1 in NPT
SeriesGFR600 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR600C25F2TK AirTAC Filter Regulator 1 in NPT

GFR600G-series filter regulator, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · See datasheet · 40 µm
One size downGFR400
Add lubricationGFC600-C2 (two-unit set)

Where the GFR600C25F2TK AirTAC Filter Regulator 1 in NPT Is Used

factory

Automotive paint shop air supply

Feeds clean, pressure-stabilised air to spray booths and air-assisted applicators, where water carryover or pressure drift would spoil finish quality on vehicle panels.

conveyor_belt

Carton-sealing conveyor line

Supplies regulated air to the pneumatic cylinders that lower, hold and release cartons on a packaging conveyor, keeping stroke timing consistent across shifts.

settings_input_component

CNC fixture clamping circuit

Sits ahead of a machining centre's pneumatic clamping manifold, filtering plant air and holding a steady clamp pressure so workpieces stay secured during cutting.

Is the GFR600C25F2TK AirTAC Filter Regulator 1 in NPT the Right Unit?

Start with the port and size: this unit is size 600 with a 1 in NPT port, the largest step in the GFR range, chosen when the line's required flow sits above what smaller 200-400 bodies serve. Because flow is published as curves rather than a single rating, send us your application's flow and pressure targets and we will confirm the correct size before you order. Drain choice matters: this configuration uses the differential-pressure drain (the default); automatic (A) or manual (M) drains are available if you prefer timed or hands-on condensate removal. Filtration is the 40 um standard element; specify the W variant for 5 um where downstream equipment needs finer air. The fitted square gauge reads in psi; MPa or bar scales are alternatives. Thread is NPT here, while PT (standard) and G (BSPP) are orderable options. A bracket is included; on some families a J code deletes it.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR600C25F2TK AirTAC Filter Regulator 1 in NPT FAQ

AirTAC publishes filter-regulator flow as performance curves rather than a single rated figure, so we do not quote one number. Tell us your application's flow and working pressure and we will confirm sizing against the datasheet curves on request before you order.

The blank drain code on this model is the differential-pressure type: condensate is discharged automatically when the pressure differential across the bowl rises, with no operator input. If you would rather have a fully automatic float drain or a manual drain you operate on a schedule, the same body is orderable with A (automatic) or M (manual) drain codes.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR600C25F2TK AirTAC Filter Regulator 1 in NPT

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR600C25F2TK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.