The AirTAC GFR600C25LC2WGK AirTAC Filter Regulator G1 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$125.48 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR600C25LC2WGK AirTAC Filter Regulator G1 Low-Pressure

The GFR600C25LC2WGK is an AirTAC GFR600 filter regulator: filtration and pressure regulation combined in a single 600-size body. It removes water and particulate from compressed air through a 5 um element (code W) and regulates downstream pressure with its low-pressure type regulator. This configuration carries a G1 (1 in) port with G thread, a differential-pressure drain that bleeds collected condensate automatically whenever the pressure differential across the element is high enough, a round pressure gauge reading in psi, and a built-in reverse/check valve that holds the downstream setting if upstream supply is interrupted. The bowl on this 600 size is aluminium alloy, and the mounting bracket is included. Maximum working (inlet) pressure is 1.0 MPa (145 psi); operating temperature is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GFR600 is the largest size in the GFR filter-regulator range, which spans sizes 200, 300, 400 and 600 with stepped ports, a choice of differential-pressure, automatic or manual drains, 40 um standard or 5 um (W) filtration, gauge and scale options, and PT, G or NPT threads. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.

GFR600C25LC2WGK AirTAC Filter Regulator G1 Low-Pressure Technical Specifications

ModelGFR600C25LC2WGK AirTAC Filter Regulator G1 Low-Pressure
SeriesGFR600 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR600C25LC2WGK AirTAC Filter Regulator G1 Low-Pressure

GFR600G-series filter regulator, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · See datasheet · 40 µm
One size downGFR400
Add lubricationGFC600-C2 (two-unit set)

Where the GFR600C25LC2WGK AirTAC Filter Regulator G1 Low-Pressure Is Used

factory

Plant air ring main branch regulation

On a factory compressed-air ring main, a 1 in branch feeding a production bay needs water and scale removed and the branch pressure held steady for every drop below it. A 600-size filter regulator with a 5 um element and a psi gauge sits at that branch take-off and conditions the whole sub-main in one body.

valve

Large pneumatic valve manifold supply

Big directional control valves and cylinder manifolds on packaging or palletising lines need clean, stable air at a set pressure to shift reliably. This filter regulator, fitted with a reverse/check valve, filters to 5 um and holds the manifold setting even if the upstream supply dips.

conveyor_belt

Conveyor actuator air preparation

Air-driven conveyor gates, stops and tensioners on a bottling or canning line run for years on whatever the main supply carries. A 5 um filter element and stable regulated pressure at the line drop keep those actuators from sticking or creeping, with the differential-pressure drain handling collected condensate.

Is the GFR600C25LC2WGK AirTAC Filter Regulator G1 Low-Pressure the Right Unit?

Step up through the GFR sizes (200 / 300 / 400 / 600) as your port and air demand grow; this unit is the 600 size on a 1 in G-threaded port, the largest step in the range. Drain choice is real: differential-pressure (as fitted here) needs no attention but only purges when the differential is high enough, automatic drains continuously, and manual drains only when you open them. Filtration is 5 um on this unit versus the 40 um standard - choose the finer grade where downstream components tolerate less particulate. Gauges are available as the embedded square type or an external round gauge in MPa, psi or bar scales; this configuration carries a round psi gauge. Threads come as PT (standard), G or NPT to order, and a bracket is included. Note that this is the low-pressure type regulator; its exact adjustment range is not published in the material we hold, so confirm it with us against your set pressure. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR600C25LC2WGK AirTAC Filter Regulator G1 Low-Pressure FAQ

AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a rated flow, Cv or SCFM number for this unit. Tell us your application and we will confirm the relevant flow data from the datasheet on request before you order.

The blank drain position in the code means the differential-pressure drain is fitted: it purges collected condensate automatically when the pressure drop across the 5 um element is high enough, with no operator attention. If your usage pattern suits continuous purging or a manually emptied bowl, the GFR600 is also available with automatic (A) or manual (M) drains - ask us for those variants.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR600C25LC2WGK AirTAC Filter Regulator G1 Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR600C25LC2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.