verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR600C25LF1TK AirTAC Filter Regulator 1 in NPT

The AirTAC GFR600C25LF1TK AirTAC Filter Regulator 1 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$125.61 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR600C25LF1TK AirTAC Filter Regulator 1 in NPT

The AirTAC GFR600C25LF1TK is a size 600 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration carries a 1 in NPT port, the standard 40 um filter element, a differential-pressure drain, and the low-pressure regulator type. It ships as coded with an embedded square gauge reading in MPa, a reverse/check valve fitted, and a mounting bracket included. The aluminium alloy bowl suits the largest frame in the G-series, with a maximum inlet pressure of 1.0 MPa (145 psi) and an operating temperature of -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and options including 5 um filtration (code W), automatic or manual drains, gauge scale choices, G (BSPP) or NPT threads in place of the PT standard, and reverse/check valves. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.

GFR600C25LF1TK AirTAC Filter Regulator 1 in NPT Technical Specifications

ModelGFR600C25LF1TK AirTAC Filter Regulator 1 in NPT
SeriesGFR600 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR600C25LF1TK AirTAC Filter Regulator 1 in NPT

GFR600G-series filter regulator, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · See datasheet · 40 µm
One size downGFR400
Add lubricationGFC600-C2 (two-unit set)

Where the GFR600C25LF1TK AirTAC Filter Regulator 1 in NPT Is Used

factory

Stamping press air drops

Conditioning the main air drop that feeds large pneumatic cylinders on a metal stamping press, where water and scale carried from the compressor must be knocked out before the line regulator sets working pressure.

settings_input_component

Packaging machine valve manifold supply

Filtering and regulating the supply ahead of the valve manifold on a cartoning or case-packing line, keeping condensate and pipe debris out of the directional valves while holding a stable set pressure.

tune

CNC pneumatic clamping circuit

Supplying a filtered, regulated air feed to the clamping circuit of a CNC machining centre, where the low-pressure regulator type sets a controlled clamp pressure and the check valve holds the line against backflow.

Is the GFR600C25LF1TK AirTAC Filter Regulator 1 in NPT the Right Unit?

Start with the port step: this unit is the 1 in NPT size 600 frame, the largest in the GFR range, so step down to a 300 or 400 if your supply line is smaller. Choose the drain to match access: differential-pressure (as coded here) drains automatically as pressure drops, automatic (A) drains continuously, and manual (M) needs a periodic bowl purge. The 40 um element as coded is the standard grade; specify W for the 5 um option where finer filtration is needed. The embedded square MPa gauge is fitted as coded, and an external round gauge with MPa, psi or bar scales is available. PT is the standard thread; G (BSPP) and NPT are catalogue options to order. Bracket included as coded; J omits it.

Be aware this is the low-pressure regulator type, so confirm the set-pressure window suits your circuit before ordering - we will confirm the exact regulation range from the datasheet on request. Flow is published as curves, not a single rating, so send us your application details and we will confirm sizing against the curves before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR600C25LF1TK AirTAC Filter Regulator 1 in NPT FAQ

AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a l/min or SCFM number. Send us your line size and application and we will confirm the flow curve and datasheet figures for this 1 in size 600 unit on request before you order.

The L in the code marks the low-pressure regulator type rather than the standard one, for circuits that work at reduced set pressures. Because the exact regulation window for this type is not published in the standard tables, confirm your set pressure with us and we will verify it against the datasheet. The rest of the decode is standard: 1 in NPT port, 40 um element, differential-pressure drain, square MPa gauge, reverse/check valve fitted, bracket included.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR600C25LF1TK AirTAC Filter Regulator 1 in NPT

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR600C25LF1TK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.