verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR600C25LJC1T AirTAC Filter Regulator NPT1 Low Pressure

The AirTAC GFR600C25LJC1T AirTAC Filter Regulator NPT1 Low Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$113.02 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR600C25LJC1T AirTAC Filter Regulator NPT1 Low Pressure

The GFR600C25LJC1T is an AirTAC GFR-series filter regulator: water and particulate filtration plus pressure regulation combined in a single body. This size 600 configuration is built around a 1 in NPT port and carries the low-pressure regulator type, a 40 um standard filtration element, a differential-pressure drain and a fitted round gauge scaled in MPa. At size 600 the bowl is aluminium alloy, and this unit is ordered without a mounting bracket. Maximum working (inlet) pressure is 1.0 MPa (145 psi), with an operating temperature range of -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GFR filter-regulator family is published in sizes 200, 300, 400 and 600, with port options, a choice of differential-pressure, automatic or manual drain, an optional 5 um element (code W), gauge scale choices (MPa, psi or bar), PT as the standard thread and G or NPT as order options, and bracket or no-bracket variants. Flow is published as curves rather than a single rated figure; we confirm the datasheet figures for your application on request.

GFR600C25LJC1T AirTAC Filter Regulator NPT1 Low Pressure Technical Specifications

ModelGFR600C25LJC1T AirTAC Filter Regulator NPT1 Low Pressure
SeriesGFR600 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR600C25LJC1T AirTAC Filter Regulator NPT1 Low Pressure

GFR600G-series filter regulator, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · See datasheet · 40 µm
One size downGFR400
Add lubricationGFC600-C2 (two-unit set)

Where the GFR600C25LJC1T AirTAC Filter Regulator NPT1 Low Pressure Is Used

factory

Low-pressure supply header on a plant air ring

Installed at the take-off point of a factory air ring, the unit filters condensed water and pipe-scale from the main supply and holds a reduced, stable pressure for a low-pressure distribution leg feeding downstream equipment.

precision_manufacturing

Pneumatic clamping circuit on a machining fixture

Mounted at the drop feeding a machining-fixture clamping circuit, the unit removes water and particulate before the valves and holds the reduced working pressure the clamp cylinders are set up for, with the MPa gauge giving the setter a direct reading.

conveyor_belt

Air preparation for a packaging-line conveyor drive

Fitted on the 1 in supply drop to a packaging line's conveyor and gating section, the unit conditions the incoming compressed air - dropping water and particles - and regulates it down to the pressure the line's actuators are set up to run at.

Is the GFR600C25LJC1T AirTAC Filter Regulator NPT1 Low Pressure the Right Unit?

Size and port are the first decision: 200, 300, 400 and 600 step up in port size and flow capacity, so match the size to the air demand of the circuit - here the 600 size with its 1 in NPT port suits the largest supply lines in the range. Drain type is a real choice: differential-pressure (as decoded here) drains automatically as the pressure differential builds, while automatic and manual variants are also available in the family. The 40 um element is standard; specify the W code for 5 um where finer filtration is needed. Gauge scale can be MPa, psi or bar - this unit carries a round gauge scaled in MPa. Thread is PT as standard, with G and NPT as catalogue options; this unit is the NPT version. Note that this is the low-pressure regulator type, so confirm the regulated pressure band suits your circuit before ordering. Because flow is published as curves and not a single rating, ask us to confirm sizing against your application before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR600C25LJC1T AirTAC Filter Regulator NPT1 Low Pressure FAQ

AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a rated flow, Cv or SCFM number. Tell us your line pressure and the air demand of the circuit and we will confirm the sizing from the datasheet curves on request before you order.

The L in the code selects the low-pressure regulator type rather than the standard type, so the regulated pressure band is different; the exact range for the low-pressure type is not published in our sheet, so we confirm it on request. The C1 code means a round external gauge scaled in MPa is fitted instead of the embedded square gauge, and the T code selects NPT thread rather than the PT standard.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR600C25LJC1T AirTAC Filter Regulator NPT1 Low Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR600C25LJC1T and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.