verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR600C25LJC1TK AirTAC Filter Regulator 1 in NPT

The AirTAC GFR600C25LJC1TK AirTAC Filter Regulator 1 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$124.42 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR600C25LJC1TK AirTAC Filter Regulator 1 in NPT

The AirTAC GFR600C25LJC1TK is a 600-size filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is built around a 1 in NPT port for high-flow main lines, with the standard 40 um filter element and a differential-pressure drain that bleeds collected condensate automatically whenever the pressure differential across the bowl is high enough - no daily manual draining on lightly loaded drops. The regulator is the low-pressure (L) type, and this unit carries the external round pressure gauge scaled in MPa plus a reverse/check valve (K) that holds downstream pressure if the upstream supply is lost. No mounting bracket is included with this code.

This is a genuine AirTAC part from the GFR filter-regulator family, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in up to 1 in, in PT (standard), G and NPT threads, with manual, automatic or differential-pressure drains, 40 um or 5 um (W) filtration, gauge choices and scale options. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet and sizing figures for your application on request.

GFR600C25LJC1TK AirTAC Filter Regulator 1 in NPT Technical Specifications

ModelGFR600C25LJC1TK AirTAC Filter Regulator 1 in NPT
SeriesGFR600 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR600C25LJC1TK AirTAC Filter Regulator 1 in NPT

GFR600G-series filter regulator, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · See datasheet · 40 µm
One size downGFR400
Add lubricationGFC600-C2 (two-unit set)

Where the GFR600C25LJC1TK AirTAC Filter Regulator 1 in NPT Is Used

factory

Plant air header regulation

Mounted on a 1 in compressed-air distribution header in a factory, it filters line-scale and condensate from the main supply and holds a steady low regulated pressure for the whole drop.

precision_manufacturing

CNC machining cell air supply

Feeding the air drops of a CNC machining cell, it cleans the incoming plant air to 40 um and regulates the supply pressure that actuates tool changers, clamps and air-powered fixtures.

conveyor_belt

Packaging and conveyor line supply

Installed at the inlet of a packaging or conveyor line, it strips water and particulate before the air reaches cylinders and actuators, with the reverse/check valve holding the circuit if upstream supply dips.

Is the GFR600C25LJC1TK AirTAC Filter Regulator 1 in NPT the Right Unit?

Size and port are the first decision: the 600 frame with its 1 in NPT connection suits main air headers and high-consumption drops, while smaller GFR sizes cover lighter lines - match the size step to the flow your line actually needs. Drain type comes next: differential-pressure (this unit) suits steady, well-loaded drops; automatic (A) drains unconditionally; manual (M) puts draining in the operator's hands. The standard 40 um element is right for general plant air; specify the W code for 5 um where downstream equipment needs finer protection. This code is the low-pressure (L) regulator type, so confirm its adjustment window against your setpoint before ordering. Gauge, thread (PT standard, G or NPT to order) and bracket options can all be chosen per code. Because flow is published as curves rather than a single rated figure, send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR600C25LJC1TK AirTAC Filter Regulator 1 in NPT FAQ

AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote one number here. Tell us your line pressure, setpoint and expected air consumption, and we will confirm the flow curve and sizing from the datasheet on request before you order.

The L code makes this a low-pressure regulator type rather than the standard version; the exact adjustment range for this type is not published in the material we hold, so confirm your setpoint with us and we will verify it against the datasheet. The C1 code means the external round gauge, scaled in MPa, is fitted; the embedded square gauge is the standard fitting and MPa, psi and bar scales are available to order.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR600C25LJC1TK AirTAC Filter Regulator 1 in NPT

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR600C25LJC1TK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.