The AirTAC GFR600C25MJC2G AirTAC Filter Regulator G1 1 in Port is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR600C25MJC2G is an AirTAC GFR600 filter regulator: one body that removes water and particulate from compressed air and regulates the pressure delivered downstream. This configuration carries a G1 (1 in) G-thread port, a manual drain, the standard 40 um filter element and an external round gauge with a psi scale, and it is the standard regulator type with no reverse/check valve fitted and no mounting bracket. The regulator adjusts from 0.05-0.9 MPa (7-130 psi), maximum inlet pressure is 1.0 MPa (145 psi), and the working temperature range is -5 to 70 C (non-freezing). At size 600 the bowl is aluminium alloy.
This is a genuine AirTAC part. The GFR filter-regulator family is available in sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, a choice of manual, automatic or differential-pressure drain, an optional 5 um element (code W), gauge scales in MPa, psi or bar, and PT as the standard thread with G and NPT as order options. Flow is published by AirTAC as curves rather than a single rated figure, so we confirm flow and datasheet figures for your application on request.
| Model | GFR600C25MJC2G AirTAC Filter Regulator G1 1 in Port |
|---|---|
| Series | GFR600 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR600 | G-series filter regulator, 600 body — sets the port range. |
|---|---|
| C2 | Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR600 · See datasheet · 40 µm |
|---|---|
| One size down | GFR400 |
| Add lubrication | GFC600-C2 (two-unit set) |
Point-of-use supply for a CNC machining centre's pneumatic clamps and tool-changer cylinders: the 40 um element strips water and pipe-scale particulate from the shop main while the regulator holds a steady set pressure to the machine, with the psi round gauge giving operators a direct readout at the drop.
Mounted at the air drop feeding carton-sealer and case-packer cylinders on a packaging line, where the one-piece filter-regulator keeps supplied air free of condensate and particulate and holds the working pressure the actuators were set up for, drained by hand during scheduled line checks.
Installed at the inlet of a plasma cutting table, where the filter section removes moisture and particulate from the shop air feeding the torch circuit and the regulator section sets the supply pressure the cutting system calls for, with the 1 in G-thread port matching the machine's main air connection.
Step up through sizes 200, 300, 400 and 600 against the flow your line needs; this size 600 unit carries the largest port in the family at G1 (1 in). Choose the drain to match maintenance practice: manual (this unit, code M) is drained by hand during routine checks, automatic (A) and differential-pressure (blank) drain unattended. Filter grade is 40 um standard; specify W for 5 um where finer particulate removal matters. The fitted round gauge here reads in psi; embedded square gauges and MPa or bar scales are the other gauge choices. Thread is G (BSPP) on this unit; PT is the catalogue standard and NPT is an order option. Code J means no mounting bracket is included. Because AirTAC publishes flow as curves rather than a single rating, ask us to confirm sizing against the datasheet before ordering.
Quick checklist
The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR600 as curves rather than a single rated figure, so we do not quote a number. Send us your application's flow and pressure requirements and we will confirm sizing against the datasheet on request before you order.
The M in the code means a manual drain: accumulated condensate is drained from the aluminium alloy bowl by hand as part of routine checks. The family also offers automatic drain (code A) and differential-pressure drain (blank), and with a manual drain the regulator adjusts from 0.05-0.9 MPa (7-130 psi).
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.