The AirTAC GFR600C25MJC2W AirTAC Filter Regulator PT1 1 in is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR600C25MJC2W is a size 600 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration has a PT1 (1 in) port with PT thread, a fine 5 um filter element (code W), a manual drain on the bowl, and a round gauge reading in psi. The standard regulator adjusts from 0.05 to 0.9 MPa (7-130 psi) with a maximum inlet pressure of 1.0 MPa (145 psi), and the unit operates from -5 to 70 C (non-freezing). At size 600 the bowl is aluminium alloy, and this code is ordered without a mounting bracket.
This is a genuine AirTAC part from the G-series filter regulator line, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in and options including differential-pressure, automatic or manual drains, 40 um or 5 um filtration, embedded square or external round gauges with MPa, psi or bar scales, and PT, G or NPT threads. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering.
| Model | GFR600C25MJC2W AirTAC Filter Regulator PT1 1 in |
|---|---|
| Series | GFR600 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR600 | G-series filter regulator, 600 body — sets the port range. |
|---|---|
| C2 | Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR600 · See datasheet · 40 µm |
|---|---|
| One size down | GFR400 |
| Add lubrication | GFC600-C2 (two-unit set) |
Feeding a 1 in main drop that supplies clamps, chucks and pneumatic tool circuits on a CNC machining line, with the 5 um element protecting downstream valves from water and fine particulate.
Conditioning and setting the pressure for air cylinders that divert, stop and lift product on a packaging or palletising conveyor, with the psi gauge giving operators a local setpoint reading.
Providing filtered, regulated air to large pneumatic rack-and-pinion actuators on process valves, where the manual drain suits a staffed plant room and the 1 in port matches the actuator supply line.
Size 600 with a 1 in port is the largest step in the GFR range; step up or down (200/300/400/600) against the flow your line needs, since larger sizes carry larger ports and more flow capacity. This unit uses a manual drain, so someone must periodically open the bowl drain; if the installation is unmanned or hard to reach, a differential-pressure or automatic drain code may suit better. The 5 um element (W) is the finer choice over the 40 um standard where downstream equipment needs cleaner air. The round psi gauge is fitted here; square embedded gauges and MPa or bar scales are alternatives. PT thread is the standard on this code, with G and NPT available as order options, and brackets are optional (this code has none).
Before ordering, note that flow for this family is published as curves, not a single rated figure. Send us your application details and we will confirm the datasheet and sizing against your required flow.
Quick checklist
The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for this family as curves rather than a single rated figure, so we do not quote a rated flow number. Tell us your application and required flow, and we will confirm the datasheet figures and check the sizing for you before you order.
The M in the code selects a manual drain: condensate collected in the aluminium alloy bowl is emptied by opening the drain when needed, which suits attended installations. The GFR family also offers a differential-pressure drain (the default) and an automatic drain (code A) for installations that are not checked regularly.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.