The AirTAC GFR600C25MJC2WG AirTAC Filter Regulator 1 in G1 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR600C25MJC2WG is a size-600 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is built around a G1 (1 in) G-thread port, a 5 um filter element (the finer of the two catalogue grades), a manual drain on the bowl, and an external round gauge reading in psi. The regulator is the standard type with an adjustment range of 0.05-0.9 MPa (7-130 psi), and the maximum working (inlet) pressure is 1.0 MPa (145 psi). At size 600 the bowl is aluminium alloy, and this unit is ordered without a mounting bracket.
This is a genuine AirTAC part from the GFR filter-regulator family, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in up to 1 in, a choice of drain types, 40 um or 5 um filtration, gauge styles and scales, and PT, G or NPT threads. Flow is published in the catalogue as curves rather than a single rated figure, so ask us to confirm sizing or any datasheet figure against your application before ordering.
| Model | GFR600C25MJC2WG AirTAC Filter Regulator 1 in G1 |
|---|---|
| Series | GFR600 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR600 | G-series filter regulator, 600 body — sets the port range. |
|---|---|
| C2 | Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR600 · See datasheet · 40 µm |
|---|---|
| One size down | GFR400 |
| Add lubrication | GFC600-C2 (two-unit set) |
Fitted at the main air drop feeding a CNC machining cell, it cleans water and chips-laden carryover out of the shop supply and holds a set pressure to the cell's valves and actuators, with the psi gauge giving operators a local reading.
On a cartoning or case-packing conveyor line, it conditions the air feeding cylinders and grippers, with the 5 um element protecting close-tolerance valve spools and the manual drain emptied during scheduled line cleans.
On a lab test rig or pilot plant skid, it filters the facility air down to 5 um and regulates it to the setpoint the experiment or instrument needs, with the round psi gauge and G1 port suiting larger rig supply lines.
Start with the size and port: the 600 series with a G1 (1 in) port is the largest step in the GFR range, so match it to the pipe size and the flow your line needs - we can check the published flow curves against your demand on request. Then set the options that this code fixes: the 5 um element (W) for finer filtration than the 40 um standard, the manual drain (M) where an operator can bleed the bowl routinely, the round psi gauge (C2), the G (BSPP) thread, and no bracket (J) where the unit mounts on existing pipework or your own panel. Note the manual-drain regulator range of 0.05-0.9 MPa (7-130 psi) and the -5 to 70 C non-freezing temperature limit.
Because the catalogue gives flow as curves rather than one rated number, we do not quote a flow figure here. Send us your application details and we will confirm the sizing and any datasheet figure you need before you order.
Quick checklist
The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves in the catalogue, not as a single rated figure, so we do not quote a flow number here. Tell us your line size and air demand and we will confirm the correct sizing from the datasheet on request.
The M code means the bowl is drained by hand, which suits installations an operator visits routinely; automatic and differential-pressure drains are available as order options if you prefer unattended draining. The W code selects the 5 um element instead of the 40 um standard, giving finer particulate removal for downstream valves and instruments.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.