verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR600C25MLJC2WK AirTAC Filter Regulator 1 in PT, 5 um

The AirTAC GFR600C25MLJC2WK AirTAC Filter Regulator 1 in PT, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$124.03 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR600C25MLJC2WK AirTAC Filter Regulator 1 in PT, 5 um

The AirTAC GFR600C25MLJC2WK is a size-600 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is built for 1 in PT threaded ports, carries the fine 5 um filter element (code W), and uses a manual drain, so an operator opens the drain at the bottom of the bowl to discharge collected condensate. It is the low-pressure (L) type, fitted with a reverse/check valve (K) and an external round gauge reading in psi, and is supplied without a mounting bracket. The size-600 bowl is aluminium alloy, and maximum working (inlet) pressure is 1.0 MPa (145 psi) with an operating temperature of -5 to 70 C (non-freezing).

This is a genuine AirTAC part from the GFR filter-regulator family, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of 40 um standard or 5 um fine filtration, differential-pressure, automatic or manual drains, standard or low-pressure regulation, embedded square or external round gauges in MPa, psi or bar scales, and PT, G or NPT threads. Flow for this family is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing figures for your application on request.

GFR600C25MLJC2WK AirTAC Filter Regulator 1 in PT, 5 um Technical Specifications

ModelGFR600C25MLJC2WK AirTAC Filter Regulator 1 in PT, 5 um
SeriesGFR600 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR600C25MLJC2WK AirTAC Filter Regulator 1 in PT, 5 um

GFR600G-series filter regulator, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · See datasheet · 40 µm
One size downGFR400
Add lubricationGFC600-C2 (two-unit set)

Where the GFR600C25MLJC2WK AirTAC Filter Regulator 1 in PT, 5 um Is Used

factory

Automotive paint shop air drops

Feeds filtered, pressure-controlled air to spray-booth and paint-line circuits on a 1 in main, where the 5 um element helps keep water and particulate out of finishing equipment and the manual drain is emptied during shift checks.

conveyor_belt

Bottling and packaging line actuators

Supplies the pneumatic clamp, pusher and gripper circuits on a bottling or cartoning conveyor, with the regulator holding a steady reduced pressure for consistent cylinder action and the manual drain cleared during planned maintenance.

settings_input_component

Plant air main take-off for machine cells

Installed as a point-of-use filter regulator on a 1 in distribution main feeding a machine cell or panel of air tools, combining water/particulate removal and low-pressure regulation in one body to save panel space.

Is the GFR600C25MLJC2WK AirTAC Filter Regulator 1 in PT, 5 um the Right Unit?

Start from the port and flow step: size 600 with 1 in PT ports sits at the top of the GFR range, so step down to GFR300/GFR400 only if your line flow is modest. Choose the drain to match attendance: manual drain (this unit) suits installations where an operator can periodically open the bowl drain; automatic or differential-pressure drains suit unattended drops. The 5 um element (W) is the right pick when downstream valves and instruments need finer filtration than the 40 um standard. This is the low-pressure (L) type, so specify it where the circuit works at reduced pressures rather than full line pressure; the exact regulation range for the low-pressure type is not published, so confirm it with us. The round psi gauge (C2) is fitted here; embedded square gauges and MPa/bar scales are the alternatives. PT is the standard thread, with G (BSPP) and NPT available as order options, and a mounting bracket can be added if this J-coded (no-bracket) unit needs one.

One honest note on sizing: AirTAC publishes flow for this family as curves, not as a single rated number, so send us your application flow and pressure and we will confirm the right size against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR600C25MLJC2WK AirTAC Filter Regulator 1 in PT, 5 um FAQ

AirTAC publishes flow for the GFR family as performance curves rather than a single rated figure, so we do not quote one number. Tell us your line flow and working pressure and we will confirm the sizing against the datasheet on request before you order.

M is the manual-drain code: an operator opens the drain under the aluminium alloy bowl to discharge collected water, which suits attended installations. W is the filter-grade code for the fine 5 um element, instead of the 40 um standard element.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR600C25MLJC2WK AirTAC Filter Regulator 1 in PT, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR600C25MLJC2WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.