verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR600C25MLNT AirTAC Filter Regulator 1 in NPT

The AirTAC GFR600C25MLNT AirTAC Filter Regulator 1 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$108.52 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR600C25MLNT AirTAC Filter Regulator 1 in NPT

The GFR600C25MLNT is an AirTAC GFR-series filter regulator: a single body that first removes water and particulate from compressed air, then regulates downstream pressure. This size-600 unit is supplied with a 1 in NPT port, a manual drain bowl in aluminium alloy, a standard 40 um filter element, and the low-pressure regulator type. No gauge is fitted on this configuration, and the mounting bracket is included.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port options from 1/8 in to 1 in, a choice of manual, automatic or differential-pressure drain, a 40 um standard or 5 um (code W) element, and PT, G or NPT threads. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm datasheet figures for your application.

GFR600C25MLNT AirTAC Filter Regulator 1 in NPT Technical Specifications

ModelGFR600C25MLNT AirTAC Filter Regulator 1 in NPT
SeriesGFR600 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR600C25MLNT AirTAC Filter Regulator 1 in NPT

GFR600G-series filter regulator, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · See datasheet · 40 µm
One size downGFR400
Add lubricationGFC600-C2 (two-unit set)

Where the GFR600C25MLNT AirTAC Filter Regulator 1 in NPT Is Used

factory

Plant air header take-off

Filtered, regulated supply tapped from a 1 in main feeding a production hall's pneumatic drop lines, with manual drain suited to a supervised compressor room.

precision_manufacturing

Pneumatic press and clamp supply

Conditioning the air feeding clamps and cylinders on a fabrication cell, where clean, regulated low-pressure air holds the fixture sequence consistent.

conveyor_belt

Packaging conveyor actuation

Supplying air to diverters, stoppers and lifters on a bottling or carton conveyor line, with the 40 um element protecting valve spools from water and debris.

Is the GFR600C25MLNT AirTAC Filter Regulator 1 in NPT the Right Unit?

Size 600 with a 1 in port is the largest step in the GFR range, so start there when the line's required flow points to the top of the family; we can check the published flow curves against your demand before you order. This unit has a manual drain, which suits installations where an operator drains the bowl as part of a routine; choose automatic or differential-pressure drain codes if the bowl cannot be attended. The 40 um element is the standard grade - specify the W code only if the application needs the 5 um option. Thread is NPT here; PT is the catalogue standard and G (BSPP) is also an order option. The included bracket simplifies wall or panel fixing. Note this is the low-pressure regulator type, and its exact adjustment range is not published - confirm it with us if your setpoint is critical.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR600C25MLNT AirTAC Filter Regulator 1 in NPT FAQ

AirTAC publishes flow for this series as curves, not as a single rated figure, so we do not quote a number that is not in the datasheet. Tell us your line demand and we will confirm the sizing against the published curves and send the datasheet on request.

The M code in GFR600C25MLNT specifies a manual drain bowl, which an operator empties as part of routine checks; automatic or differential-pressure drain versions are available if the bowl cannot be attended. The N code means no gauge is fitted on this configuration, so add a gauge variant if you need a visible setpoint. This is also the low-pressure regulator type; its exact adjustment range is not published, so confirm it with us before ordering.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR600C25MLNT AirTAC Filter Regulator 1 in NPT

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR600C25MLNT and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.