AirTAC 4V Solenoid Valve Guide: Order Code, Voltage and Port Sizes
How to read an AirTAC 4V100 to 4V400 order code: body size, 5/2 and 5/3 functions, coil voltage letters, port and exhaust sizes, and the M5 and NPT rules.
Every AirTAC 4V solenoid valve code is built the same way. Read it left to right: 4V 2 10 - 08 B I G = 4V valve, 200 body, single solenoid 5/2, 1/4" ports, DC24V coil, grommet lead, G thread.
The order code, position by position
| Position | Example | Options |
|---|---|---|
| Series | 4V | 4V = 5-port solenoid valve (5/2 or 5/3) |
| Body | 2 | 1 = 4V100, 2 = 4V200, 3 = 4V300, 4 = 4V400 |
| Function | 10 | 10, 20, 30C, 30E, 30P (see below) |
| Port size | 08 | M5; 06 = 1/8"; 08 = 1/4"; 10 = 3/8"; 15 = 1/2" |
| Coil voltage | B | A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V |
| Electrical entry | I | blank = terminal (DIN connector), I = grommet with 0.5 m leads |
| Port thread | G | blank = PT, G = G (BSPP), T = NPT; no letter on M5 valves |
M5 valves have no thread letter. M5 is a metric thread, so a code such as 4V110-M5BT does not exist. Order 4V110-M5B and use M5 fittings.
Body sizes, ports and flow
| Model | Ports P, A, B | Exhaust R, S | Effective area (Cv) | Max. cycles/s (5/2) | Weight 5/2 single (g) |
|---|---|---|---|---|---|
| 4V110-M5 | M5 | M5 | - | 5 | 120 |
| 4V110-06 | 1/8" | 1/8" | 10.2 mm² (Cv 0.6) | 5 | 120 |
| 4V210-06 | 1/8" | 1/8" | - | 5 | 220 |
| 4V210-08 | 1/4" | 1/8" | 17.0 mm² (Cv 1.0) | 5 | 220 |
| 4V310-08 | 1/4" | 1/4" | - | 4 | 310 |
| 4V310-10 | 3/8" | 1/4" | 28.0 mm² (Cv 1.65) | 4 | 310 |
| 4V410-15 | 1/2" | 1/2" | 48.0 mm² (Cv 2.82) | 3 | 590 |
All bodies: air filtered to 40 µm, 0.15 to 0.8 MPa, proof pressure 1.2 MPa, -20 to 70 °C, no lubrication needed, internal or external pilot. 5/3 models switch at up to 3 cycles per second and flow slightly less: 4V230C-08 is 13.6 mm² (Cv 0.8), 4V330C-10 21.3 mm² (Cv 1.25), 4V430C-15 40.0 mm² (Cv 2.35).
5/2 or 5/3: valve functions
| Code | Function | What happens | Models |
|---|---|---|---|
| 10 | 5/2, single solenoid | Spring return: the valve goes back to its rest position when power is removed, so the signal has to stay on. The usual choice for most cylinders. | 4V110, 4V210, 4V310, 4V410 |
| 20 | 5/2, double solenoid | Memory function: a short pulse on either coil switches the valve and it stays there after the power is removed. | 4V120, 4V220, 4V320, 4V420 |
| 30C | 5/3, closed center | With both coils off all ports are blocked and the cylinder holds its position (within the limits of air leakage). | 4V130C, 4V230C, 4V330C, 4V430C |
| 30E | 5/3, exhaust center | With both coils off both cylinder ports exhaust and the supply is blocked, so the cylinder can be moved by hand. | 4V130E, 4V230E, 4V330E, 4V430E |
| 30P | 5/3, pressure center | With both coils off supply pressure goes to both cylinder ports. | 4V130P, 4V230P, 4V330P, 4V430P |
A 5/3 valve needs two coils and is used when the cylinder must stop mid-stroke (closed center), be released for manual movement (exhaust center) or be pushed from both sides (pressure center). For a cylinder that only extends and retracts, a 5/2 valve is enough.
Coil voltage codes
| Code | Voltage | Power 4V100 | Power 4V200 / 300 / 400 | Allowed variation |
|---|---|---|---|---|
| A | AC220V | 3.5 VA | 4.5 VA | ±15% |
| B | DC24V | 2.8 W | 3.0 W | ±10% |
| C | AC110V | 3.5 VA | 4.5 VA | ±15% |
| E | AC24V | 4.0 VA | 5.0 VA | ±15% |
| F | DC12V | 2.5 W | 2.5 W | ±10% |
For North American control panels the usual choices are B (DC24V) or C (AC110V), with T for NPT ports.
Exhaust ports that are smaller than the working ports
Two bodies have smaller exhaust ports (R and S) than working ports (P, A, B). Order exhaust silencers or fittings in the exhaust size:
- 4V210-08, 4V220-08 and 4V230C/E/P-08: ports 1/4", exhaust 1/8".
- 4V310-10, 4V320-10 and 4V330C/E/P-10: ports 3/8", exhaust 1/4".
- All other 4V bodies: exhaust the same size as the working ports.
Silencers: BSL sintered silencers. Fittings: PC push-in fittings. For NPT valves use NPT fittings.
Frequently asked questions
What does 4V210-08 mean?
4V200 body, single solenoid 5/2-way valve (10), 1/4 inch working ports (08). The letter after it is the coil voltage, for example 4V210-08B is DC24V, and G or T at the end selects G or NPT ports instead of PT.
What is the exhaust port size of a 4V210-08?
1/8 inch. The working ports P, A and B are 1/4 inch but the exhaust ports R and S are 1/8 inch, so exhaust silencers must be 1/8 inch. The 4V310-10 likewise has 3/8 inch ports and 1/4 inch exhausts.
What is the difference between 4V230C, 4V230E and 4V230P?
All three are 5/3-way double-solenoid valves. With both coils off, C (closed center) blocks all ports, E (exhaust center) vents both cylinder ports and P (pressure center) supplies both cylinder ports.
Which letter is DC24V on an AirTAC 4V valve?
B. A is AC220V, C is AC110V, E is AC24V and F is DC12V.
Can I order a 4V110-M5 with NPT thread?
No. M5 is a metric thread and M5 valves have no thread letter. Use M5 fittings.
Have a part number, a nameplate photo or a BOM? Send it and we reply with prices and the matching AirTAC order codes within 7 hours.
Request a quote