The AirTAC 4V220-06 Solenoid Valve, 4V200 Series (4V22006A-AM) is a genuine 5/2-way double solenoid (memory) solenoid valve with PT1/8 ports and an effective area of 17.0 mm² (Cv 1.0). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The 4V22006A-AM is a 4V200-series double-solenoid 5/2 directional valve fitted with an AMISCO (Italian) coil and wired for AC220V through a terminal box. Because it is double solenoid, it has no return spring: it stays in whichever position it was last switched to, held by land friction and balanced pressure with no holding current, so a momentary pulse is enough to shift it. This memory behaviour makes it a natural fit for latching circuits where both a start and a stop signal exist.
Porting is PT 1/8in on all five ways, with an effective area of 17 mm2 (Cv 1.0) that comfortably feeds double-acting cylinders in the ~O32-50 mm range. Switching is crisp at 0.05 s or better and the valve cycles up to 5 times per second. It weighs 320 g, carries an IP65 terminal box and needs no lubrication. Note that the AMISCO coil replaces the standard AirTAC coil - its exact electrical rating should be confirmed with us before ordering.
| Model | AirTAC 4V220-06 Solenoid Valve, 4V200 Series (4V22006A-AM) |
|---|---|
| Series | 4V200 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Double solenoid (memory) |
| Port size | PT1/8 |
| Exhaust port | PT1/8 |
| Effective area (Cv) | 17.0 mm² (Cv 1.0) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 5 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 320 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 17.0 mm² |
|---|---|
| Flow coefficient | Cv 1.0 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 2 | Body size (4V200) — sets port & flow. |
| 2 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -06 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.
Two pushbuttons or sensors pulse the two coils to clamp and release a double-acting cylinder; the spool remembers the last command even after a power cut.
Cv 1.0 (catalog figure for the 4V210-08) flow cycles pushers that kick cartons on conveyors at up to 5 strokes per second, with the 0.05 s response keeping timing tight.
Mount several 4V220-06 bodies on one manifold base to build a compact valve island for assembly or testing stations wired at AC220V.
Pick this valve when you want a latching 5/2 at 1/8in porting: Cv 1.0 (catalog figure for the 4V210-08) suits mid-size double-acting cylinders around O32-50 mm. Step down to the 4V100 (Cv 0.6) for a small bore or low-flow duty, or move to the 4V300 (Cv 1.65) if a larger cylinder or a faster stroke demands more air. If your circuit needs a guaranteed mid-position (hold, float or pressurise both sides), that is a 4V230C/E/P 5/3 valve, not this 5/2. A single valve on its own sub-base, or several valves ganged on an integrated manifold, are both supported.
For a like-for-like swap, match five points: 4V200 body, double-solenoid 5/2 function, 1/8in PT port, AC220V coil, terminal entry - plus the AMISCO coil option (-AM) if your line specifies it.
Quick checklist
Its 5/2 spool offers 17 mm2 effective area (Cv 1.0), sized for double-acting cylinders of roughly O32 to 50 mm bore at normal cycle rates. A 5/2 valve pressurises one cylinder side while exhausting the other, so it is not suitable for single-acting cylinders, which need a 3/2 valve.
The -AM suffix means the valve ships with a factory-fitted AMISCO (Italian) solenoid coil instead of the standard AirTAC coil; the body, 5/2 memory function, PT1/8in ports and flow performance are unchanged. The ordered voltage is still AC220V with terminal-box entry, but please confirm the exact AMISCO coil VA rating with us for your documentation.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.