The AirTAC 4V230C-06 Solenoid Valve, 4V200 Series (4V230C06B-W) is a genuine 5/3-way 5/3 double solenoid — closed center solenoid valve with PT1/8 ports and an effective area of 13.6 mm² (Cv 0.8). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The 4V230C06B-W is a 5/3-way double-solenoid valve in AirTAC's 4V200 mid-body series, built here with the -W external-pilot option: pilot air arrives through its own external port rather than being tapped from the main line, so the spool keeps switching cleanly on low-pressure or vacuum-fed circuits where an internal-pilot valve would stall. At the center position all ports are blocked, which parks a double-acting cylinder where it stopped.
Flow sits at 13.6 mm2 effective area (Cv 0.8, catalog figure for the 4V230C-08), and switching response is 0.05 s or better. The DC24V coil draws just 3.0 W through a terminal-box entry, and the aluminum body weighs 360 g. Suits roughly O32-50 mm bores; for guaranteed suspended-load holding, pair the blocked center with a pilot-operated check valve or a mechanical brake.
| Model | AirTAC 4V230C-06 Solenoid Valve, 4V200 Series (4V230C06B-W) |
|---|---|
| Series | 4V200 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Closed center |
| Port size | PT1/8 |
| Exhaust port | PT1/8 |
| Effective area (Cv) | 13.6 mm² (Cv 0.8) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 360 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 13.6 mm² |
|---|---|
| Flow coefficient | Cv 0.8 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 2 | Body size (4V200) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -06 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.
The external pilot feed keeps the 30C spool stroking reliably on lines running near the bottom of the 0.15-0.8 MPa range or on vacuum/low-pressure circuits.
Closed-center blocking parks a double-acting actuator exactly where the pulse left it on assembly fixtures and index stops; back it with a check valve for suspended loads.
Mount on a 4V200 base to build a multi-valve group where one 24 V DC supply and one external pilot line serve every valve in the rack.
Choose this external-pilot 4V230C when your supply pressure drops or fluctuates and internal pilot tapping would cause missed shifts; if pressure is stable and you do not need center-block holding, a double-solenoid 5/2 (function 20) gives you Cv 1.0 and 5 cycles/sec instead of 3. Downsize to the 4V100 (Cv 0.6) for small bores, or step up to the 4V300 (Cv 1.65) when a larger cylinder needs more flow.
Before ordering a replacement, match all five points: 4V200 body, function 30C closed center, 1/8" port in PT thread, DC24V coil, and terminal-box entry. Single valves mount directly; add a manifold base to bank several together in one compact station.
Quick checklist
It converts the valve to external pilot. Instead of bleeding pilot air from the main supply, you connect a separate pilot port, so the valve switches dependably even when line pressure is low or the circuit runs under vacuum. All other specs stay those of the 4V200 5/3 body: Cv 0.8 (catalog figure for the 4V230C-08), 3 cycles/sec maximum, 360 g, 0.05 s response.
When both solenoids are off, every port blocks, so a double-acting cylinder between O32 and 50 mm holds its last position. The 24 V DC coil (3.0 W) is memory-type too: a pulse shifts the spool and it stays until the opposite pulse arrives. Treat this as positioning, not fall protection - a suspended load still needs a pilot-operated check valve or mechanical brake.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.