The AirTAC 4V210-06 Solenoid Valve, 4V200 Series (4V21006B-W) is a genuine 5/2-way single solenoid (spring return) solenoid valve with PT1/8 ports and an effective area of 17.0 mm² (Cv 1.0). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V21006B-W is the external-pilot version of the compact 4V200 body in a 5/2 single-solenoid layout. Energise the DC24V coil (3.0 W) and pressurised air is directed to one side of a double-acting cylinder while the other side vents; de-energise and the internal spring snaps the spool back to its rest position, so the valve needs a constant electrical signal to stay switched. Unlike the standard internally-piloted 4V210, the -W variant feeds its pilot stage from a dedicated external port, which keeps switching dependable on low-pressure mains or in vacuum / low-pressure circuits where an internal pilot tap would not have enough force to shift the spool.
Performance sits squarely in the 4V200 mid-body class: effective area 17 mm2 (Cv 1.0), maximum cycling of 5 cycles per second, and an activating response of 0.05 s or less - ample for bores in the ~O32-50 mm range. The 1/8in PT (Rc tapered) ports suit smaller lines, the aluminium body weighs just 220 g, and wiring lands on a conventional terminal box. IP65 (DIN40050) sealing and B-class insulation protect the coil in washdown-prone assembly and packaging cells.
| Model | AirTAC 4V210-06 Solenoid Valve, 4V200 Series (4V21006B-W) |
|---|---|
| Series | 4V200 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Single solenoid (spring return) |
| Port size | PT1/8 |
| Exhaust port | PT1/8 |
| Effective area (Cv) | 17.0 mm² (Cv 1.0) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 5 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 220 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 17.0 mm² |
|---|---|
| Flow coefficient | Cv 1.0 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 2 | Body size (4V200) — sets port & flow. |
| 1 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -06 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.
The external pilot port takes its switching air from a separate feed, so the 4V21006B-W keeps snapping over on mains that run too low to shift an internally-piloted spool.
Spring return puts a double-acting clamp back to its safe rest position the instant the DC24V signal drops - a fail-position behaviour fixture designers rely on.
With Cv 1.0 (catalog figure for the 4V210-08) and a response of 0.05 s or less, the valve cycles O32-50 mm push cylinders briskly at up to 5 cycles per second along conveyor and sorting stations.
Choose this SKU when your mains pressure is low, variable, or when the valve sits in a vacuum / low-pressure circuit - the external pilot gets its switching signal independently of line pressure. If your supply is a normal 0.15-0.8 MPa and you want simpler plumbing, the standard internally-piloted 4V210-06B does the same 5/2 job without a pilot line. Step down to the 4V100 (Cv 0.6) for very small bores, or up to the 4V300 (Cv 1.65) for larger cylinders or faster cycles. Prefer position memory over spring return? The double-solenoid 4V220 holds its last pulsed state without continuous power.
Ordering a replacement: match all five points - body size (4V200), function (single solenoid 5/2 with the -W external pilot), port and thread (1/8in, PT), coil voltage (DC24V, 3.0 W), and electrical entry (terminal box, not grommet). One valve plus a base also fits an integrated 4V200 manifold group for multi-valve stations.
Quick checklist
It is a 5/2 valve rated Cv 1.0 (catalog figure for the 4V210-08) (17 mm2 effective area), so it directs compressed air to double-acting cylinders and actuators in the ~O32-50 mm bore range. The -W suffix means the pilot stage is fed from a separate external port rather than tapped from the main supply, letting the valve switch reliably where line pressure is low or in vacuum / low-pressure circuits.
The single solenoid uses spring return: while the DC24V coil (3.0 W) is energised the valve stays in its working position, and when the signal is removed the spring returns the spool to rest, reversing the cylinder. Wiring is via the built-in terminal box - no pre-wired lead. A manual override lets you cycle the valve by hand during setup or troubleshooting.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.