verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 4V Series · 5/3-way Solenoid Valve

AirTAC 4V230E-06 Solenoid Valve, 4V200 Series (4V230E06B-W)

The AirTAC 4V230E-06 Solenoid Valve, 4V200 Series (4V230E06B-W) is a genuine 5/3-way 5/3 double solenoid — exhaust center solenoid valve with PT1/8 ports and an effective area of 13.6 mm² (Cv 0.8). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/3-way
  • Function5/3 double solenoid — Exhaust center
  • Port sizePT1/8
  • Effective area13.6 mm²
  • Flow (Cv)0.8
  • Series4V200
$53.63 $58.64Save 8% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every 4V230E-06 stroke, mounting and version on one page All 4V230E-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC 4V230E-06 Solenoid Valve, 4V200 Series (4V230E06B-W)

The 4V230E06B-W is the externally piloted -W variant of AirTAC's 4V230E-06B: a 5/3-way double-solenoid valve with an exhaust center, built in the 4V200 mid-body class for double-acting cylinders and actuators. At rest the spool blocks supply while venting both cylinder ports, so a connected double-acting cylinder drifts freely by external force rather than holding rigid position. The 1/8" port carries an effective area of 13.6 mm2 (Cv 0.8, catalog figure for the 4V230C-08), and the valve suits roughly O32-50 mm bores where its Cv 0.8 (catalog figure for the 4V230C-08) flow class is the right match. Because the -W option feeds the pilot from a separate external port instead of tapping the main line internally, the valve keeps switching dependably in low main-pressure or vacuum service where an internally piloted valve would fail to shift.

The center-exhaust behavior is worth planning for: on power loss or a neutral command, the cylinder is unloaded, so anything needing firm retention needs a pilot-operated check valve or mechanical brake downstream. Weight is a trim 360 g, the DC24V terminal-box coil draws 3.0 W, and the spool responds in 0.05 s or less. Manual override is fitted, lubrication-free operation is standard, and the valve stacks onto a common base as part of an integrated manifold group.

AirTAC 4V230E-06 Solenoid Valve, 4V200 Series (4V230E06B-W) Technical Specifications

ModelAirTAC 4V230E-06 Solenoid Valve, 4V200 Series (4V230E06B-W)
Series4V200 solenoid valve (spool type)
Valve type5/3-way
Function5/3 double solenoid — Exhaust center
Port sizePT1/8
Exhaust portPT1/8
Effective area (Cv)13.6 mm² (Cv 0.8)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency3 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight360 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area13.6 mm²
Flow coefficientCv 0.8
Response time≤ 0.05 s
Coil powerAC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: AirTAC 4V230E-06 Solenoid Valve, 4V200 Series (4V230E06B-W)

4VSolenoid valve, spool type, 4-series.
2Body size (4V200) — sets port & flow.
3Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-06Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the AirTAC 4V230E-06 Solenoid Valve, 4V200 Series (4V230E06B-W) Is Used

valve

Low-pressure pneumatic circuits

External pilot supply keeps the spool shifting where an internally piloted valve would stall, making the -W build the right pick for low main-pressure lines and vacuum-assisted circuits.

conveyor_belt

Packaging and diverting actuators

The exhaust center lets pushers and diverters on packaging lines move aside under product or tooling weight while de-energized, releasing the actuator between cycles.

settings_input_component

Multi-station manifold assembly

Mounted on a common base, the 360 g valve groups with neighbouring 4V200 stations to run clamp-and-place double-acting cylinders from one compact air supply.

Is the AirTAC 4V230E-06 Solenoid Valve, 4V200 Series (4V230E06B-W) the Right Valve?

Size by bore and cycle rate: the 4V200 5/3 body delivers Cv 0.8 (catalog figure for the 4V230C-08), so step down to the 4V100 (Cv 0.6) for small O25-class cylinders or step up to the 4V300 (Cv 1.65) for larger bores and faster cycles. Choose exhaust center (this model) when the cylinder should float at neutral, closed center when it must hold position, or pressure center to bias both sides. Pick the -W external-pilot build if your circuit runs at low or unstable main pressure, and a single valve versus a manifold base depending on how many stations share one supply. For a direct replacement, match all five points: 4V200 body, 30E function, 1/8" PT thread, DC24V coil, and terminal electrical entry.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

AirTAC 4V230E-06 Solenoid Valve, 4V200 Series (4V230E06B-W) FAQ

Instead of the pilot stage being fed from the main supply inside the valve, pilot air arrives through a separate external port. That means the spool still switches when main-line pressure is low or the circuit is under vacuum, and it does so with a 13.6 mm2 (Cv 0.8, catalog figure for the 4V230C-08) flow path and a sub-0.05 s response.

No. With the center exhausting, both cylinder ports vent, so a double-acting cylinder floats and can be moved by external force. If you need firm load retention, add a pilot-operated check valve at the cylinder ports or a mechanical brake; the valve itself does not act as a safety brake.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC 4V230E-06 Solenoid Valve, 4V200 Series (4V230E06B-W)

Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for 4V230E06B-W and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.