The AirTAC 4V230E-06 Solenoid Valve, 4V200 Series (4V230E06B-W) is a genuine 5/3-way 5/3 double solenoid — exhaust center solenoid valve with PT1/8 ports and an effective area of 13.6 mm² (Cv 0.8). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The 4V230E06B-W is the externally piloted -W variant of AirTAC's 4V230E-06B: a 5/3-way double-solenoid valve with an exhaust center, built in the 4V200 mid-body class for double-acting cylinders and actuators. At rest the spool blocks supply while venting both cylinder ports, so a connected double-acting cylinder drifts freely by external force rather than holding rigid position. The 1/8" port carries an effective area of 13.6 mm2 (Cv 0.8, catalog figure for the 4V230C-08), and the valve suits roughly O32-50 mm bores where its Cv 0.8 (catalog figure for the 4V230C-08) flow class is the right match. Because the -W option feeds the pilot from a separate external port instead of tapping the main line internally, the valve keeps switching dependably in low main-pressure or vacuum service where an internally piloted valve would fail to shift.
The center-exhaust behavior is worth planning for: on power loss or a neutral command, the cylinder is unloaded, so anything needing firm retention needs a pilot-operated check valve or mechanical brake downstream. Weight is a trim 360 g, the DC24V terminal-box coil draws 3.0 W, and the spool responds in 0.05 s or less. Manual override is fitted, lubrication-free operation is standard, and the valve stacks onto a common base as part of an integrated manifold group.
| Model | AirTAC 4V230E-06 Solenoid Valve, 4V200 Series (4V230E06B-W) |
|---|---|
| Series | 4V200 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Exhaust center |
| Port size | PT1/8 |
| Exhaust port | PT1/8 |
| Effective area (Cv) | 13.6 mm² (Cv 0.8) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 360 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 13.6 mm² |
|---|---|
| Flow coefficient | Cv 0.8 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 2 | Body size (4V200) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -06 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.
External pilot supply keeps the spool shifting where an internally piloted valve would stall, making the -W build the right pick for low main-pressure lines and vacuum-assisted circuits.
The exhaust center lets pushers and diverters on packaging lines move aside under product or tooling weight while de-energized, releasing the actuator between cycles.
Mounted on a common base, the 360 g valve groups with neighbouring 4V200 stations to run clamp-and-place double-acting cylinders from one compact air supply.
Size by bore and cycle rate: the 4V200 5/3 body delivers Cv 0.8 (catalog figure for the 4V230C-08), so step down to the 4V100 (Cv 0.6) for small O25-class cylinders or step up to the 4V300 (Cv 1.65) for larger bores and faster cycles. Choose exhaust center (this model) when the cylinder should float at neutral, closed center when it must hold position, or pressure center to bias both sides. Pick the -W external-pilot build if your circuit runs at low or unstable main pressure, and a single valve versus a manifold base depending on how many stations share one supply. For a direct replacement, match all five points: 4V200 body, 30E function, 1/8" PT thread, DC24V coil, and terminal electrical entry.
Quick checklist
Instead of the pilot stage being fed from the main supply inside the valve, pilot air arrives through a separate external port. That means the spool still switches when main-line pressure is low or the circuit is under vacuum, and it does so with a 13.6 mm2 (Cv 0.8, catalog figure for the 4V230C-08) flow path and a sub-0.05 s response.
No. With the center exhausting, both cylinder ports vent, so a double-acting cylinder floats and can be moved by external force. If you need firm load retention, add a pilot-operated check valve at the cylinder ports or a mechanical brake; the valve itself does not act as a safety brake.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.