This model is discontinued
AirTAC has phased out the MAL series. The drop-in replacement is ACED40X50 — same bore, stroke, output force, port and mounting, so it fits the same application. Simply order the ACED40X50 in place of this model. The ACE replacement is a current-production ISO 21287 compact cylinder in the same bore, stroke and force class, with a matching short body and the same mounting-accessory family, so it fits the same envelope. Confirm mounting-interface dimensions against the ACE datasheet before ordering.

The AirTAC Airtac ACPD Double Rod Compact Cylinder ACPD40X50 is a double acting, double rod DIN-standard tight/compact air cylinder with a Ø40mm bore and 50mm stroke, 1/8" air ports and a hard-anodized aluminium body. This model is discontinued — the current-production replacement is the ACED40X50 (ISO 21287 ACE), in the same bore, stroke and force class.
A double acting compact cylinder with a rod leaving both covers, the ACPD40X50 pushes and pulls with the same 571.8 N at 0.5 MPa because each stroke works on the rod-side area. The 40 mm bore and 50 mm stroke suit tight pick-and-place heads, and the through-rod on the far end can carry a sensor flag or a second tool while resisting rotation and side load. Its hard-anodized aluminium body keeps the mounting length about 50% shorter than an ISO 15552 profile cylinder.
At 0.7 MPa the output rises to 800.5 N in either direction, with 116.6 kgf available at the full 1.0 MPa rating. As a planning figure, treat roughly 343 N as the usable push at 0.5 MPa, which lifts about 29 kg vertically with a 2:1 margin. A fixed TPU bumper sits at each end, the S45C hard-chrome rod runs 30-500 mm/s, and the magnet is not fitted on this code - order the -S variant if you need CMSE / DMSE switches. This model is discontinued; the current-production replacement is ACED40X50.
| Model | Airtac ACPD Double Rod Compact Cylinder ACPD40X50 |
|---|---|
| Series | ACPD DIN compact cylinder (discontinued) |
| Replacement | ACED40X50 |
| Bore size | Ø40 mm |
| Stroke | 50 mm |
| Acting type | Double acting, double rod |
| Port size | 1/8" |
| Rod thread | M8×1.25 |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Operating pressure | 0.15 – 1.0 MPa |
| Proof pressure | 1.5 MPa |
| Temperature | -20 to +70 °C |
| Speed range | 30 – 500 mm/s |
| Cushion | Fixed bumper (both ends) |
| Max standard stroke | Up to 200 mm |
Specifications follow the official AirTAC ACP datasheet (now discontinued). The ACED40X50 (ISO 21287) carries the same bore/stroke/force class; confirm mounting-interface dimensions against the ACE datasheet before installation. Rod type: female thread (blank) or male thread (B). Thread options: PT (blank) / G.
| Pressure | Force (both ways) |
|---|---|
| 0.5 MPa | 572 N |
| 0.7 MPa | 800 N |
| Max (@1.0 MPa) | 117 kgf |
Double-rod: a rod exits both covers, so output force is equal in both directions (rod-side area used).
| ACPD | DIN compact cylinder (double-rod, discontinued). |
|---|---|
| 40 | Bore size in mm. |
| ×50 | Stroke length in mm. |
| S | Optional built-in magnet for sensor position sensing (omit for no magnet). |
| B | Rod type: B = male thread; blank = female thread. |
Replacement mapping (swap P for E): ACP→ACE, ASP→ASE, ATP→ATE, ACPD→ACED, ACPJ→ACEJ. ACP-family: ACP (double acting), ASP / ATP (single acting push / pull), ACPD (double rod), ACPJ (adjustable stroke).
The 571.8 N symmetric output at 0.5 MPa ejects finished 40 mm bar stock from a lathe fixture, with the rear rod driving a chip-clearing flag.
A 50 mm stroke swings a reject flap on a filler conveyor; the through-rod resists the side load of the flap and keeps alignment over millions of cycles.
Equal force in both directions clamps and releases cartons at 0.7 MPa (800.5 N), with the fixed TPU bumpers absorbing end-of-stroke shock at 30-500 mm/s.
Size between the 32 mm bore (345.6 N at 0.5 MPa) and the 50 mm bore (881.2 N at 0.5 MPa) depending on your fixture load; this 40 mm version delivers 571.8 N both ways at 0.5 MPa. Remember the piston drifts when air is lost - add a rod lock or pilot check if the load must stay put. FA/FB flange or LB foot mounts bolt to the ISO 21287 face, and the optional -S magnet enables CMSE / DMSE switch sensing. Since ACPD40X50 is discontinued, spec ACED40X50 as the drop-in and confirm the ISO 21287 mounting dimensions before swapping.
Replacement checklist
It is a double-rod cylinder, so force is equal both ways: 571.8 N at 0.5 MPa and 800.5 N at 0.7 MPa, on the rod-side area. At the 1.0 MPa maximum it reaches 116.6 kgf. Operating range is 0.15-1.0 MPa (22-145 psi), proof pressure 1.5 MPa (215 psi), speed 30-500 mm/s, and the bore-40 port is 1/8" (PT thread).
The ACPD family is no longer produced; order ACED40X50, the ISO 21287 successor in the same bore, stroke and force class. Confirm the ISO 21287 mounting dimensions before the swap since the ACP is DIN-standard. For sensing, the magnet is the optional -S code - this plain model has no magnet, so specify ACPD40X50S (or the ACED equivalent) to run CMSE / DMSE switches.
Send us the quantity and destination. We confirm price, stock and lead time on the ACED40X50 replacement — usually within 7-8 hours.